Technical data
Brocade VDX 6720 Hardware Reference Manual 57
53-1002084-06
Regulatory certifications
A
CAUTION
For a DC system, use a grounding wire of at least 14 American Wire Gauge (AWG). The 14 AWG
wire should be attached to an agency-approved crimp connector (Tyco 34120 or certified Lug),
crimped with the proper crimping tool and attached to the protective grounding lug, using a size
#6-32 screw and a star washer, on the chassis with the other end to building ground. Each DC-DC
power supply must have a separate grounding cable.
Regulatory certifications
Table 16 lists the regulatory compliance standards for which the Brocade VDX 6720 is certified.
Environmental regulation compliance
This section describes the “China RoHS” environmental regulatory compliance requirements for
the Brocade VDX 6720 switch.
China RoHS
The contents included in this section are per the requirements of the People's Republic of China-
Management Methods for Controlling Pollution by Electronic Information products.
TABLE 16 Regulatory compliance standards
Country Standards Agency certifications and markings
Safety EMC Safety EMC
United States Bi-Nat UL/CSA 60950-1
2nd Ed or latest
ANSI C63.4 cCSAus FCC Class A and
Statement
Canada Bi-Nat UL/CSA 60950-1
2nd Ed or latest
ICES-003 Class A cCSAus ICES A and Statement
Japan CISPR22 and JEIDA
(Harmonics)
VCCI-A and Statement
European Union EN60950-1 or latest EN55022 and EN55024 TUV-GS CE marking
Australia, New Zealand EN55022 and CISPR22
or AS/NZS CISPR22
C-Tick mark
Argentina IEC60950-1 or latest “S” mark
Russia IEC60950-1 or latest 51318.22-99 and
51318.24.99 or latest
GOST mark GOST mark
Korea KN22 and KN24 KCC mark Class A
China GB4943-2001 and
GB9254-1998 or latest
GB17625.1-2003 or
latest
CCC logo CCC logo
Taiwan CNS 14336(94) or latest CNS 13438(95) or latest BSMI mark BSMI mark