Technical data
40 Brocade VDX 6720 Hardware Reference Manual
53-1002084-06
Replacing a fan assembly in the Brocade VDX 6720-60
5
FIGURE 18 Brocade VDX 6720-60 fan assemblies on the non-port side
ATTENTION
Maintain all power supply and fan assemblies in operational condition to provide redundancy.
CAUTION
Because the cooling system relies on pressurized air, do not leave any of the power supply and
fan assembly slots empty longer than two minutes while the switch is operating. If a power supply
or fan assembly fails, leave it in the switch until it can be replaced.
CAUTION
Disassembling any part of the power supply and fan assembly voids the warranty and regulatory
certifications. There are no user-serviceable parts inside the power supply and fan assembly.
Table 8 describes the fan assembly status LED colors, behaviors, and actions required, if any.
1 Fan assembly #3 3 Fan assembly #1
2 Fan assembly #2
1
2
3
TABLE 8 Brocade VDX 6720-60 fan assembly status LED behavior, description, and required
actions
LED color and behavior Description Action required
Off (no light) Fan assembly is not receiving power. Verify that the fan assembly is
seated correctly.