Technical data

2 Brocade VDX 6720 Hardware Reference Manual
53-1002084-06
Brocade VDX 6720 overview
1
Support for inter-switch link (ISL) trunking
- Frame-level hardware-based trunking (even distribution of frames across trunk links)
A reduced-depth, rack-mount design using existing rail kits (fixed, mid-mount, or Telco rack
mount kits
Extensive diagnostics and system-monitoring capabilities for enhanced high Reliability,
Availability, and Serviceability (RAS)
Optimized airflow (a choice of front-to-back or back-to-front flow)
A real-time clock (RTC) with battery
SEEPROM for switch identification
Voltage monitoring
Fan monitoring
Three temperature sensors
I
2
C interface to monitor and control environmental aspects
NOTE
Port numbering for the Brocade VDX 6720 begins with 1, not 0.
VDX 6720-24 features
Features specific to the Brocade VDX 6720-24 include:
1U form factor enclosure
16 10 GbE SFP+ ports (also configurable to 1 GbE) with 8 additional 10 GbE ports available for
a total of 24
One forwarding ASIC
600 nanosecond (ns) port-to-port latency
15-inch depth
Dual, hot-swappable 250W AC power supplies with three integrated cooling fans each
VDX 6720-60 features
Features specific to the Brocade VDX 6720-60 include:
2U form factor enclosure
40 10 GbE SFP+ ports (also configurable to 1 GbE) with 20 additional 10 GbE ports available
for a total of 60
Nine forwarding ASICs arranged in a 3/6, core/edge configuration
One forwarding FC ASIC
600 ns port-to-port latency, 1.8μs across port groups
17-inch depth
Dual, redundant, hot-swappable 500W AC power supplies
Triple, hot-swappable cooling fans in an n+1 configuration