Technical data

30 Brocade VA-40FC Hardware Reference Manual
53-1001540-04
Environmental requirements
A
Environmental requirements
Table 6 lists the acceptable environmental ranges for both operating and nonoperating (such as
during transportation or storage) conditions.
General specifications
Table 7 lists the general specifications for the Brocade VA-40FC.
TABLE 6 Environmental Requirements
Condition Acceptable During Operation Acceptable During Non-Operation
Ambient
Temperature
0 to 40 Celsius
(32
to 104 Fahrenheit)
-25
to 70 Celsius
(-13
to 158 Fahrenheit)
Humidity 10% to 85% RH non-condensing, at
40 Celsius (104
Fahrenheit), with maximum
gradient of 10% per hour
10% to 90% RH non-condensing, at 70°
Celsius (158
Fahrenheit)
Altitude 3,000 meters (9,842 feet) above sea level 0 to 12 kilometers (39,370 feet) above sea
level
Shock 20 G, 6 ms, half-sine wave Half sine, 33G 11ms, 3/e.g. Axis
Vibration 0.5 G sine, 0.4 grms random, 5-500 Hz 2.0 G sine, 1.1 grms random 5-500 Hz
Air flow High speed, 13,000 RPM,
49.3 CMH (29 CFM)
Low speed, 7000 RPM,
37.4 CMH (22 CFM)
None required
TABLE 7 General Specifications
Specification Description
Configurable port types E_Port, F_Port, FL_Port, M_Port, and EX_Port
System architecture Nonblocking shared-memory switch
System processor Power PC 440EPX,667 MHz CPU
ANSI Fibre Channel protocol FC-PH (Fibre Channel Physical and Signalling Interface standard)
Modes of operation Fibre Channel Class 2 and Class 3
Fabric initialization Complies with FC-SW-3 Rev. 6.6
FC-IP (IP over Fibre Channel) Complies with FC-IP 2.3 of FCA profile
Aggregate switch I/O bandwidth 640 Gbps if all 40 ports are running at 8 Gbps, full duplex
Port-to-port latency 700 nanoseconds