Specifications

Table Of Contents
camTest
85Fabric OS Version 3.1.x/4.1.x Reference Guide
domain and area fields of the SID zeroed. If a miss is expected (when the walking
1 or walking 0 pattern is used) the original SID in the frame transmitted is
received unchanged.
Note: This command may not be executed on an enabled switch. You must first disable
the switch using the switchDisable command.
Operands
This command has the following operand:
Example
To verify that Content Addressable Memory (CAM) is functioning correctly in
V3.1.x:
To verify that CAM is functioning correctly in V4.1.x:
passcnt
(V3.1.x only)
Specify the number of times to perform this test. The
default value is 1.
--slot number
(V4.1.x only)
Specify the slot number that the diagnostic will operate
on. The ports specified will be relative to this slot
number. The default is set to 0 and is designed to
operate on fixed port count products.
-passcnt count
(V4.1.x only)
Specify the number of times to perform this test. The
default value is 1.
-txport itemlist
(V4.1.x only)
Specify a list of blade ports to test. By default, all the
blade ports in the specified slot (--slot) will be used.
See the itemlist help pages for further details.
switch:admin> camtest
Running CAM Test .............. passed.
switch:admin> camtest -txports 1/1
Running CAM Test ..............Test Complete: "camtest" Pass 1 of 1
Duration 0 hr, 0 min & 5 sec (0:0:5:14).
passed.