Specifications

Table Of Contents
Fabric OS Commands
832 Fabric OS Version 3.1.x/4.1.x Reference Guide
The policy parameters determine the number of failed or non-operational units for
each contributor that trigger a status change in the switch. For example, if the
FaultyPorts DOWN parameter is set to 3, and 3 ports fail in the switch, then the
status of the switch changes to DOWN.
Operands
None.
Example
To display the switch status policy:
See Also
switchStatusPolicySet
switchStatusShow
Fans 2 1
PortStatus 0 0
ISLStatus 2 1
Table 17: Contributor Value and Status (Continued)
Contributor
Default Value for
DOWN
Default Value
for MARGINAL
switch:admin> switchStatusPolicyShow
The current overall switch status policy parameters:
Down Marginal
----------------------------------
FaultyPorts 1 0
MissingSFPs 0 1
PowerSupplies 2 1
Temperatures 3 1
Fans 3 1
PortStatus 0 0