sramRetentionTest
785Fabric OS Version 3.1.x/4.1.x Reference Guide
For details about the patterns used in diagnostic tests, see the datatypeshow
command.
Operands
This command has the following operand:
Example
To run a data retention test:
Errors
Below are the possible error messages if failures are detected:
For V3.1.x:
DIAG-REGERR
DIAG-REGERR_UNRST
DIAG-BUS_TIMEOUT
passCount
(V3.1.x only)
Specify the number of times to execute the test. The default
value is 1. This operand is optional.
--slot number
(V4.1.x only)
Specify the slot number that the diagnostic will operate
on. The ports specified will be relative to this slot number.
The default is set to 0 and designed to operate on fixed
port count products.
-passcnt count
(V4.1.x only)
Specify the number of times to execute this test. The default
value is 1. <q> to stop
-ports itemlist
(V4.1.x only)
Specify a list of blade ports to test. By default all the blade
ports in the specified slot will be used. See itemlist
for more details.
-skip bitmask
(V4.1.x only)
Specify a patterns to skip in the test. This command will
use the data patterns described above by default. Using
this option, the user can intentionally skip one or more
pattern(s) if needed.
-delay value
(V4.1.x only)
Specify the delay between the read and write in seconds.
The default value is 10, which is 10 seconds.
switch:admin> sramRetentionTest
Running SRAM Retention Test ... passed.