Specifications

Table Of Contents
Fabric OS Commands
758 Fabric OS Version 3.1.x/4.1.x Reference Guide
For Finisar “smart” SFPs, five additional fields are displayed:
Module temperature
Voltage
Received optical power
Transmitted optical power (longwave only)
Laser diode drive current
Operands
This command has the following operands:
Example
The example below shows SFP summary information:
slotnumber
(V4.1.x only)
Specify the slot number for a StorageWorks Core switch. For
all other switches this operand is not required. The slot number
must be followed by a slash ( / ) and the port number, so that
each port is represented by both slot number (1 through 4, or
7 through 10), and port number (0 through 15).
The StorageWorks Core switch has a total of 1–10 slots. Slot
number 5 and 6 are control processor cards, and slot 1
through 4, and 7 through 10, are port cards. On each port
card, there are 16 ports counted from the bottom, 0 to 15.
portnumber Specify a port number. Valid values for port number vary
depending on the switch type. This operand is optional.
switch:admin> sfpshow
port 0: id (sw) Vendor: AGILENT Serial No: A00128928
port 1: id (sw) Vendor: AGILENT Serial No: A00128983
port 2: id (sw) Vendor: AGILENT Serial No: A00128966
port 3: id (sw) Vendor: AGILENT Serial No: A00128929
port 4: id (sw) Vendor: AGILENT Serial No: A00128988
port 5: id (sw) Vendor: AGILENT Serial No: A00127279
port 6: id (sw) Vendor: AGILENT Serial No: A00127399
port 7: id (sw) Vendor: AGILENT Serial No: A00127264
switch:admin>