Specifications

Table Of Contents
psShow
631Fabric OS Version 3.1.x/4.1.x Reference Guide
Displays power supply status.
Synopsis
psShow
Availability
All users.
Release
V3.1.x and V4.1.x
Description
Use this command to display the current status of the switch power supplies.
The format of the display varies according to the switch model and number of
power supplies present. Optionally, depending upon switch model, the OEM
Serial ID Data is displayed after each power supply status line.
The StorageWorks Core switch cannot display power supply status:
Power Supply status not available on this switch model.
The status of each supply is shown as:
Operands
None.
psShow
OK Power supply functioning correctly.
absent Power supply not present.
Unknown Unknown power supply unit installed.
Predicting Failure Power supply is present, but predicting failure.
faulty Power supply present but faulty (no power cable, power
switch turned off, fuse blown, or other internal error).