Specifications

Table Of Contents
Fabric OS Commands
604 Fabric OS Version 3.1.x/4.1.x Reference Guide
portPhys Port physical state:
No_Card - No interface card present
No_Module - No module (SFP or other) present
No_Light - Module not receiving light
No_Sync - Receiving light but out of sync
In_Sync - Receiving light and in sync
Laser_Flt - Module is signaling a laser fault
Port_Flt - Port marked faulty
Diag_Flt - Port failed diagnostics
Lock_Ref - Locking to the reference signal
portScn Last state change notification for port.
portId 24-bit D_ID for port.
portWwn Port WWNs of devices connected.
Distance The port's long distance level.
Speed The port's fixed speed level or negotiated speed level:
1 Gbps - Fixed speed of 1 Gb per second.
N1 Gbps - Negotiated speed of 1 Gb per second.
2 Gbps - Fixed speed of 2 Gb per second.
N2 Gbps - Negotiated speed of 2 Gb per second.
Negotiating - The speed of the port is being
determined.
Interrupts Total number of interrupts.
Unknown Interrupts that are not counted elsewhere.
Lli Low-level interface (physical state, primitive seqs).
Proc_rqrd Frames delivered for embedded N_Port processing.
Timed_out Frames that have timed out.
Rx_flushed Frames requiring translation.
Tx_unavail Frames returned from an unavailable transmitter.
Free_buffer Free buffer available interrupts.
Overrun Buffer overrun interrupts.
Suspended Transmission suspended interrupts.
Table 15: PortShow Display Fields (Continued)
Field Description