Specifications
Table Of Contents
- Contents
- About this Guide
- Fabric OS Commands
- agtcfgDefault
- agtcfgSet
- agtcfgShow
- aliasDelete
- aliasJoin
- aliasPurge
- aliasShow
- aliAdd
- aliCreate
- aliDelete
- aliRemove
- aliShow
- backplanetest
- backPort
- backSpace
- bannerset
- bannershow
- bcastShow
- bladeBeacon
- bladeDiag
- bladeDiagShort
- bladedisable
- bladeenable
- bladePropShow
- bsn
- camTest
- centralMemoryTest
- cfgactvshow
- cfgAdd
- cfgClear
- cfgCreate
- cfgDelete
- cfgDisable
- cfgEnable
- cfgRemove
- cfgSave
- cfgShow
- cfgsize
- cfgTransAbort
- cfgtransshow
- chassisName
- chassisShow
- chippropshow
- chipregshow
- cmemRetentionTest
- cmiTest
- configDefault
- configDownload
- configShow
- configUpload
- configure
- Table 2: Configure Command Fabric Parameters (Continued)
- Table 3: Configure Command Virtual Channel Settings
- Table 4: Configure Command Arbitrated Loop Settings
- Table 5: Configure Command System Services Parameters
- Table 6: Configure Command Portlog Events Parameters (Continued)
- crossPortTest
- dataTypeShow
- date
- dbgshow
- diagClearError
- diagCommandShow
- diagDisablePost
- diagEnablePost
- diagesdports
- diagfaillimit
- diagHelp
- diagloopid
- diagmodepr
- diagpost
- diagretry
- diagsetburnin
- diagsetcycle
- diagshow
- diagshowtime
- diagsilkworm
- diagskiptests
- diagstopburnin
- dlsReset
- dlsSet
- dlsShow
- dnsconfig
- errClear
- errDump
- errNvLogSizeSet
- errNvLogSizeShow
- errSaveLvlSet
- errSaveLvlShow
- errShow
- Table 7: Diagnostic Error Codes (Sheet 4 of 4)
- exit
- fabportshow
- fabretryshow
- fabricprincipal
- fabricShow
- fabstateclear
- fabstateshow
- fabStatsShow
- fabswitchshow
- fanDisable
- fanEnable
- fanShow
- fashow
- faStatsShow
- fastboot
- fazoneAdd
- fazoneCreate
- fazoneDelete
- fazoneRemove
- fazoneShow
- fcpprobeshow
- fcprlsshow
- fdmicacheshow
- fdmishow
- filterTest
- Table 8: List of Filter Test Numbers, Definitions, and Action Types
- firmwareCommit
- firmwareDownload
- firmwaredownloadstatus
- firmwarerestore
- firmwareshow
- fporttest
- fspfShow
- Table 9: Display Fields (Continued)
- fwAlarmsFilterSet
- fwAlarmsFilterShow
- fwClassInit
- fwConfigReload
- fwConfigure
- Table 10: fwConfigure Fabric Watch Classes and Areas (Continued)
- fwFruCfg
- fwHelp
- fwMailCfg
- fwsamshow
- fwSetToCustom
- fwSetToDefault
- fwShow
- gbicShow
- h
- haDisable
- hadump
- haEnable
- haFailover
- haShow
- hasyncstart
- hasyncstop
- help
- historyLastShow
- historymode
- historyShow
- i
- Table 11: Command Field Description (Continued)
- ifModeSet
- ifModeShow
- ifShow
- interfaceShow
- iodReset
- iodSet
- iodShow
- ipAddrSet
- ipAddrShow
- islshow
- itemlist
- Table 12: Object Descriptions
- killtelnet
- ledtest
- licenseAdd
- licenseHelp
- licenseIdShow
- licenseRemove
- licenseShow
- linkCost
- login
- logout
- loopPortTest
- LSDbShow
- Table 13: LSDbShow Display Fields (Continued)
- mcastShow
- Table 14: Group Fields
- memshow
- mscapabilityshow
- msConfigure
- msPlatShow
- msPlClearDB
- msPlMgmtActivate
- msPlMgmtDeactivate
- msTdDisable
- msTdEnable
- msTDReadConfig
- myid
- nbrStatsClear
- nbrStateShow
- nodefind
- nsaliasshow
- nsAllShow
- nscamshow
- nsShow
- nsstatshow
- nszonemember
- parityCheck
- passwd
- pdshow
- perfAddEEMonitor
- perfAddIPMonitor
- perfAddReadMonitor
- perfAddRWMonitor
- perfAddSCSIMonitor
- perfAddUserMonitor
- perfAddWriteMonitor
- perfCfgClear
- perfCfgRestore
- perfCfgSave
- perfcleareemonitor
- perfclearfiltermonitor
- perfClrAlpaCrc
- perfDelEEMonitor
- perfDelFilterMonitor
- perfHelp
- perfSetPortEEMask
- perfShowAlpaCrc
- perfShowEEMonitor
- perfShowFilterMonitor
- perfShowPortEEMask
- pkicreate
- pkiremove
- pkishow
- portcamshow
- portcfgdefault
- portCfgEport
- portCfgGport
- portcfgislmode
- portCfgLongDistance
- portCfgLport
- portcfgpersistentdisable
- portcfgpersistentenable
- portCfgShow
- portCfgSpeed
- portCfgTrunkport
- portdebug
- portDisable
- portEnable
- portErrShow
- portflagsshow
- portLEDTest
- portLogClear
- portLogDump
- portLogDumpPort
- portloginshow
- portlogpdisc
- portLogShow
- portlogshowport
- portLoopbackTest
- portname
- portPerfShow
- portRegTest
- portRouteShow
- portShow
- Table 15: PortShow Display Fields (Continued)
- portstatsclear
- portStatsShow
- portswap
- portswapdisable
- portswapenable
- portswapshow
- porttest
- porttestshow
- powerofflistset
- powerofflistshow
- psShow
- ptdatashow
- ptphantomshow
- ptpropshow
- ptregshow
- ptrouteshow
- ptstatsshow
- qlDisable
- qlEnable
- qloopAdd
- qloopCreate
- qloopDelete
- qloopRemove
- qloopShow
- qlPartner
- qlPortDisable
- qlPortEnable
- qlPortShowAll
- qlShow
- qlStatsShow
- quietMode
- ramTest
- reboot
- routeHelp
- savecore
- secfabricshow
- secfcsfailover
- sechelp
- secmodedisable
- secmodeenable
- secmodeshow
- secnonfcspasswd
- secpolicyabort
- secpolicyactivate
- secpolicyadd
- secpolicycreate
- secpolicydelete
- secpolicydump
- secpolicyfcsmove
- secpolicyremove
- secpolicysave
- secpolicyshow
- secstatsreset
- secstatsshow
- sectemppasswdreset
- sectemppasswdset
- sectransabort
- secversionreset
- sensorShow
- setdbg
- setesdmode
- setgbicmode
- setsfpmode
- setSplbMode
- setverbose
- sfpShow
- slotOff
- slotOn
- slotpoweroff
- slotpoweron
- slotShow
- snmpMibCapSet
- spinFab
- spinSilk
- sramRetentionTest
- snn
- statsTest
- stopporttest
- supportShow
- switchBeacon
- switchcfgpersistentdisable
- switchcfgpersistentenable
- switchCfgSpeed
- switchCfgTrunk
- switchDisable
- switchEnable
- switchName
- switchReboot
- switchShow
- switchShutdown
- switchStart
- switchStatusPolicySet
- Table 16: Contributor Value and Status (Continued)
- switchStatusPolicyShow
- Table 17: Contributor Value and Status (Continued)
- switchStatusShow
- switchuptime
- syslogdIpAdd
- syslogdIpRemove
- syslogdIpShow
- systemtest
- systemverification
- tempShow
- timeout
- topologyShow
- trackChangesHelp
- trackChangesSet
- trackChangesShow
- trunkDebug
- trunkShow
- tsclockserver
- tshelp
- tstimezone
- turboRamTest
- txdpathtest
- uptime
- uRouteConfig
- uRouteRemove
- uRouteShow
- version
- wwn
- zoneAdd
- zoneCreate
- zoneDelete
- zoneHelp
- zoneRemove
- zoneShow
- Fabric OS Commands for Licensed Products
- Fabric OS Version Comparison
- Fabric and Switch Management
- Control Processor Commands
- Security Commands
- Glossary
- Index

Fabric OS Commands
206 Fabric OS Version 3.1.x/4.1.x Reference Guide
■ The state of the Central Memory based on the results of diagnostic executions
since the last reboot. OK is displayed if previous centralmemorytest
executions passed. FAULTY is displayed if the switch failed
centralmemorytest.
■ The total diagnostic frames transmitted and received since last reboot.
The sums represent the cumulative number of frames transmitted and received
by the diagnostic functional tests (portloopbacktest,
crossporttest, or spinsilk for the transmitted count only) for all
ports since the last reboot.
For example, if the switch is rebooted with POST disabled, diagshow will
show the total as 0. The values are not necessarily equal. They are not equal
when an error occurs in one of the ports during one of the tests above.
This command may also be looped by specifying the nSeconds operand. For
example, diagshow 4 executes diagshow every 4 seconds continuously
until stopped by a keyboard interrupt. This may be used to isolate a bad SFP. A
port with changing “LLI_errs” value prefixed by “**” indicates port is detecting
more errors.
Operands
This command has the following operands:
nSeconds
(V3.1.x only)
Specify the display interval (in seconds) between
repeated executions of diagShow. The default value
if no operand is specified or operand value is 0 is to
print the information once only. This operand is
optional.
--slot slotnumber
(V4.1.x only)
Specify the slot to display. If no slot is specified this
command executes on all slots in the logical switch.
This operand is optional.
-uports itemlist
(V4.1.x only)
Specify a list of user ports to display. This operand is
optional.
-bports itemlist
(V4.1.x only)
Specify a list of blade ports to display. This operand is
optional.
-use_bports value
(V4.1.x only)
If value is set to none zero, then the diagnostics status
for the blade ports specified in use_bports will be
displayed, otherwise the UI ports specified in
-uports is displayed. The default value is 0. This
operand is optional.