Specifications

Table Of Contents
crossPortTest
169Fabric OS Version 3.1.x/4.1.x Reference Guide
Example
To execute a functional test of all the ports on a switch 100 times:
-gbic_mode mode
(V4.1.x only)
The gbic_mode parameter may be used to override
the global GBIC mode described above for the
duration of this test. Specify 1 enable gbic_mode,
and the testing is limited to user ports with GBICs or
SFPs installed.
-norestore mode
(V4.1.x only)
Specify 1 to
force the test to skip part of the post-test
cleanup normally performed. This may be helpful
during debug. This parameter should normally be left
at the default value of 0.
-ports itemlist
(V4.1.x only)
Specify a list of user ports to test. By default all of the
user ports in the current switch or logical switch will
be tested. This option may be used to restrict testing to
the specified ports.
switch:admin> crossporttest 100, 1
Running Cross Port Test .......
One moment please ...
switchName: switch
switchType: 2.2
switchState: Testing
switchRole: Disabled
switchDomain: 1 (unconfirmed)
switchId: fffc01
switchWwn: 10:00:00:60:69:00:73:71
port 0: cu Testing Loopback->15
port 1: sw Testing Loopback->11
port 2: sw Testing Loopback->6
port 3: lw Testing Loopback->4
port 4: lw Testing Loopback->3
port 5: sw Testing Loopback->8
port 6: sw Testing Loopback->2
port 7: sw Testing Loopback->12
port 8: sw Testing Loopback->5
port 9: sw Testing Loopback->14
port 10: sw Testing Loopback->13
port 11: sw Testing Loopback->1
port 12: sw Testing Loopback->7
port 13: sw Testing Loopback->10
port 14: sw Testing Loopback->9
port 15: cu Testing Loopback->0
Passed.
switch:admin>