Installation guide

40 Brocade NetIron CES 2000 and NetIron CER 2000 Hardware Installation Guide
53-1001834-01
PC or terminal attachment
2
You need to assign an IP address using the CLI. You can access the CLI by attaching a serial cable
to the Console port. After you assign an IP address, you can access the system through Telnet or
IronView Network Manager.
Attaching a PC or terminal
Follow the steps given below to attach a management station using the serial port.
1. Connect a PC or terminal to the serial port of the system using a straight-through cable. The
serial port has a male DB-9 connector.
NOTE
You need to run a terminal emulation program on the PC.
2. Open the terminal emulation program and set the session parameters as follows:
Baud: 9600 bps
Data bits: 8
Parity: None
Stop bits: 1
Flow control: None
When you establish the serial connection to the system, press Enter to display the CLI prompt in the
terminal emulation window. For example:
NetIron>
If you see this of these prompt, you are now connected to the system and can proceed to
“Password assignment on page 41.
You can customize the prompt by changing the system name. For more information, refer to the
NetIron Configuration Guide.
If you do not see one of these prompts, follow the instructions given below.
1. Make sure the cable is securely connected to your PC and to the Brocade system.
2. Check the settings in your terminal emulation program. In addition to the session settings
listed above, make sure the terminal emulation session is running on the same serial port you
attached to the Brocade system.
The EIA/TIA 232 serial communication port serves as a connection point for management by a PC
or SNMP workstation.