Installation guide

Brocade NetIron CES 2000 and NetIron CER 2000 Hardware Installation Guide 39
53-1001834-01
PC or terminal attachment
2
The software regularly polls the hardware for power status information. You can display the status
information from any management session. In addition, the software automatically generates a
Syslog message and SNMP trap if a status change occurs.
PC or terminal attachment
To assign an IP address, you must have access to the Command Line Interface (CLI). The CLI is a
text-based interface that can be accessed through a direct serial connection to the device and
through Telnet connections.
TABLE 8 LEDs for power for the 2048 models
LED Position State Meaning
Fan (labeled Fn) Left side of front
panel
Green The fan tray is powered on and is operating
normal.
Amber/Green
Blinking
The fan tray is not plugged in.
Amber The fan tray is plugged in but one or more fans
are faulty.
PS1 (labeled P1) Left side of front
panel
Off Power supply 1 is not installed or is not
providing power.
Amber Power supply 1 is installed, but not connected
or a fault is detected.
Green blinking Supply has input power, but AC output is not
enabled.
Green Power supply 1 is installed and is functioning
normally.
PS2 (labeled P2) Left side of front
panel
Off Power supply 2 is not installed or is not
providing power.
Amber Power supply 2 is installed, but not connected
or a fault is detected.
Green blinking Supply has input power, but AC output is not
enabled.
Green Power supply 2 is installed and is functioning
normally.
Power Supplies DC - same indications for both DC power supplies
DC Right side of front
panel
Off Power supply is not installed or is not providing
power
Amber Power supply is installed, but not connected or
a fault is detected.
Green blinking Supply has input power, but DC output is not
enabled.
Green Supply has DC power, is enabled, and has good
output.