Installation guide

16 Brocade NetIron CES 2000 and NetIron CER 2000 Hardware Installation Guide
53-1001834-01
Hardware features
1
Port 1/23:
Type : Copper
Vendor: , Version: Unknown
Part# : Unknown, Serial#: Unknown
Port 1/24:
Type : Copper
Vendor: , Version: Unknown
Part# : Unknown, Serial#: Unknown
Port 2/1:
Type : 10GBASE-SR/SW (XFP)
Vendor: Brocade Communications, Version: 00
Part# : FTLX8511D3-F1 , Serial#: KCP02X8
Port 2/2:
Type : 10GBASE-SR/SW (XFP)
Vendor: Brocade Communications, Version: 02
Part# : TRF2000EN-LF251 , Serial#: T07J23170
All show media done
Syntax: show media
Power supplies
Each NetIron CES 2000 and NetIron CER 2000 Series device comes with one alternating-current
(AC) power supply. All models have two power supply slots, enabling you to install a second power
supply for redundancy.
NOTE
Changes or modifications made to this device that are not expressly approved by the party
responsible for compliance could void the user's authority to operate the equipment.
The power supplies can be swapped in or out of the device while the device is running. You can
remove and insert a power supply without opening the chassis. The remaining supply provides
enough power for the entire system.
The following sections provide further details about the power supplies for the NetIron CES 2000
and NetIron CER 2000 Series of devices:
Power status LEDs are listed in “Observing the power status LEDs” on page 38.
Hardware specifications for the power supplies are listed in “Hardware specifications” on
page 105.
About redundant power supplies and power supply failure” on page 17