Installation guide
110 Brocade NetIron CES 2000 and NetIron CER 2000 Hardware Installation Guide
53-1001834-01
Port specifications
C
Serial cable options between the NetIron CES 2000 and NetIron CER 2000 Series device and a PC
or terminal are shown in Figure 46.
NOTE
As indicated in Figure 45 and Figure 46, some of the wires should not be connected. If you do
connect the wires that are labeled “Reserved”, you might get unexpected results with some
terminals.
FIGURE 46 Console port pin assignments showing cable connection options to a terminal or PC
Management port pin assignments
The management port is an RJ-45 UTP connector. Table 24 describes the connector’s pin
assignments.
TABLE 24 Management port pin assignments
Pin number MDI-X ports
1TD+
2TD-
3RD+
4Not used (10BaseT)
CMT (100BaseTX)
5Not used (10BaseT)
CMT (100BaseTX)
6RD-
7Not used (10BaseT)
CMT (100BaseTX)
8Not used (10BaseT)
CMT (100BaseTX)
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
8
3
2
20
7
6
4
5
22
1
2
3
4
5
6
7
8
9
DB-9 to DB-9
Female Switch
Terminal or PC
Reserved
Reserved
Reserved
Reserved
DB-9 to DB-25
Female Switch
Terminal or PC
Reserved
Reserved
Reserved
Reserved