Installation guide

66 Brocade FastIron LS and FastIron LS-STK Hardware Installation Guide
53-1002187-01
Redundant power supply specifications
7
DRAFT: BROCADE CONFIDENTIAL
AC power supply
The FastIron LS and LS-STK devicees include an integrated AC power supply with a standard IEC
type (IEC320) input connector, that operates at 85 VAC to 254 VAC input, universal or wide input.
AC power specifications
Power cables
All FastIron devices ship with US-compatible power cables unless otherwise specified at the time of
order. United Kingdom- and European-compatible power cables are also available.
Redundant power supply specifications
The optional Redundant Power Supply (RPS2-EIF) can supply backup power to four attached
devicees (FLS627, FLS648, FLS624-STK and FLS648-STK) in the event of an AC power loss or the
failure of an internal power supply.
For more information, see “Installing a redundant power supply” on page 17.
10GBase-XFP MMF LC connector for XFP module 62.5 1310 nm 200 m
MMF 50 160 or 200 and
400 or 500
200 m
10GBase-ZR SMF LC connector for XFP module 9 1550 nm up to 80000
(80 km)
10GBase-ZRD SMF LC connector for XFP module 9 1530.33 –
1561.42 nm
up to 80000
(80 km)
TABLE 23 Cable specifications (Continued)
Cable type Connector type Core diameter
(microns)
Modal bandwidth
(MHz km) or
Wavelength (nm)
Range (meters)
TABLE 24 AC power specifications
Property FLS624 FLS648
Input voltage range 100 - 240 VAC 100 - 240 VAC
Input current < 3 Amps < 3 Amps
Inrush current < 8.5 Amps peak maximum < 12 Amps peak maximum
Power consumption
(without modules)
65 W 85 W
Power consumption
(with all modules)
105 W 120 W
Max output power 156 W 156 W