30 Brocade FastIron LS and FastIron LS-STK Hardware Installation Guide
53-1002187-01
Upgrading hardware
DRAFT: BROCADE CONFIDENTIAL
1. Remove any power cables from the device.
2. If the device is mounted in an equipment rack, remove it from the rack and place the device in
a static-free work area.
3. Put on the supplied ESD wrist strap and attach the clip end to a metal surface (such as an
equipment rack) to act as ground.
4. Disassemble the device as follows (see Figure 26 on page 30):
Use a Phillips screwdriver to remove the two screws in the bottom corners of each side. If
rack mounting ears are installed, remove the four screws that hold each ear to the device.
Turn the device so that the front (where the port connectors are) is facing you.
Slide the cover backwards to free the lip edge of the cover from the front plate. Make sure
the cover is completely free of the front panel.
FIGURE 26 Removing cover screws on FLS devices.
5. Remove the cover by sliding slightly to the rear of the device and then lifting the cover off as
shown in Figure 27.
FIGURE 27 Removing the cover from FLS devices.
FLS 624
Fastlron
LS
624
1
Fastlron LS
624
F
L
S
6
2
4