Installing a redundant power supply
2
DRAFT: BROCADE CONFIDENTIAL
FIGURE 18 RPS2-EIF Status LEDs
Installing a redundant power supply
Installation
An RPS device may be placed on a desktop or mounted in a rack.
DANGER
DO NOT place an RPS device on the floor as the case is not waterproof. It is recommended that
RPS devices be installed in a network equipment rack.
Selecting a site
RPS2-EIF units can be mounted in a standard 19 inch equipment rack or on a flat surface. When
choosing a location, follow the guidelines below:
1 Port Indicators 2 System Indicators
TABLE 7 RPS2-EIF status LEDs
LED (1~4) Condition Status
Link Off The port does not have a valid connection to a device.
On Yellow The port has a valid connection to a device.
Flashing Yellow There has been a RPS device internal power failure.
Activity Off The port is not providing power to the connected device.
Flashing Green The port has been shut down due to one of the following conditions:
• The system has detected an over-current condition.
• One or more of the fans have failed.
On Green The port is providing power to a connected device.
TABLE 8 RPS2-EIF power status LED
LED Condition Status
Power On Green AC power is being supplied to the RPS.
Off No AC power is being supplied to the RPS device.