Installation guide

14 Brocade FastIron LS and FastIron LS-STK Hardware Installation Guide
53-1002187-01
Preparing the installation site
2
DRAFT: BROCADE CONFIDENTIAL
Desktop installation
FIGURE 13 Attaching the adhesive feet
1. Attach the four adhesive feet to the bottom of the first device.
2. Set the device on a flat desktop, table, or shelf near an AC power source. Make sure that
adequate ventilation is provided for the system – a 3 inch clearance is recommended on each
side.
3. If you are installing a single device, go to “Powering on the system” on page 26.
4. If you are installing multiple devicees, attach the adhesive feet to each device. Place each
device squarely on top of the one below, in any order.
5. If you are also installing a redundant power supply, place it close to the device.
Rack mount installation
NOTE
You need a #2 Phillips screwdriver for installation.
Before mounting the device in a rack, pay particular attention to the following factors:
Temperature: Since the temperature inside a rack assembly may be higher than the ambient
room temperature, make sure the rack-environment temperature is within the specified
operating temperature range. (Refer to “Operating environment” on page 60.)
Mechanical loading: Do not place any equipment on top of a rack-mounted unit.
Circuit overloading: Be sure that the supply circuit to the rack assembly is not overloaded.
Grounding: Rack-mounted equipment should be properly grounded. Particular attention should
be given to supply connections other than direct connections to the mains.
Follow the steps below to mount devices in rack.
1. Remove the rack mount kit from the shipping carton. The kit contains two L-shaped mounting
brackets and mounting screws.
2. Attach the mounting brackets to the sides of the device as illustrated in Figure 14.