Installation guide
6 Brocade FastIron LS and FastIron LS-STK Hardware Installation Guide
53-1002187-01
Hardware features
1
DRAFT: BROCADE CONFIDENTIAL
FIGURE 10 System status LEDs
1System status LED
TABLE 3 System status LEDs
LED Condition Status
Power Green Internal power is operating normally.
Amber Internal power supply failure.
Off Power off or failure.
Diag Green System self-diagnostic test successfully completed.
Amber System self-diagnostic test has detected a fault.
RPS Green Redundant power supply is providing power.
Amber Primary power supply is active, RPS is on standby.
Off Redundant power supply is off or not plugged in.
Stack Active
controller
Green Device is the Active Controller of the stack. State may include topology
discovery, IP assignment, or normal operations.
Flashing Green Device is the Active Controller of the stack, system is initializing.
Amber Device is operating as a Standby Controller in the stack.
Flashing Amber System in Active Controller arbitration or election state.
Off System in standalone mode.
Stack Link Green Uplink and downlink operating normally.
Flashing Green Uplink has failed.
Flashing Amber Downlink has failed.
Off No stacking link present.
Module Green An expansion module is installed and operating normally.
Amber An expansion module is installed but has failed.
Off There is no module installed.
Stack ID 1-8 Indicates the device stack ID.
The Active Controller is numbered 1. (Note that If the Active Controller
fails and a backup unit takes over, the stack IDs do not change.)
The Standby Controller is numbered 2. The remaining stack members
are numbered 3-8.
0 A standalone device. A device with a stack ID of 0 cannot act as part
of a stack.
1
FLS 624
Fastlron LS 624