Installation guide
DIAG LED
DIAG LEDTABLE 7
LED State Status of hardware Recommended action
Off (no light) Diagnostic is off. No action required.
Blinking green System self-diagnostic test is in progress. No action required.
Steady green System self-diagnostic test is successfully completed. Device reboots
and clears back to off.
No action required.
Steady amber System self-diagnostic test has detected a fault. Contact support.
Management port status LED
Management port status LEDTABLE 8
LED State Status of hardware Recommended action
Off (no light) Not cabled. No action required
Blinking There is traffic and packets are being transmitted or received. No action required.
Steady No traffic being transmitted, but link is up. No action required.
1/10 GbE SFP+ port LEDs
1/10 GbE SFP+ port LEDsTABLE 9
LED State Status of hardware Recommended action
Green Link is up in 10 GbE mode. No action required.
Blinking green There is 10 GbE activity (traffic) and packets are being transmitted or
received.
No action required.
Amber Link is up in 1 GbE mode. No action required.
Blinking amber There is 1 GbE activity (traffic) and packets are being transmitted or
received.
No action required.
Brocade ICX 6650 Operation
52 Brocade ICX 6650 Hardware Installation Guide
53-1003398-01