Installation guide
NOTE
You must run a terminal emulation program on the PC.
2. Launch the terminal emulation program and set the following session parameters:
• Baud: 9600 bps
• Data bits: 8
• Parity: None
• Stop bits: 1
• Flow control: None
The console serial communication port serves as a connection point for management by a PC.
Powering on the system
After you complete the physical installation, you can power on the system.
1. Remove the power cable from the shipping package container.
2. Attach the AC power cable to the AC connector on the rear panel.
3. Insert the power cable plug into a 100V-240V outlet.
NOTE
To turn the system off, simply unplug the power cable or cables.
NOTE
The socket should be installed near the equipment and should be easily accessible.
Power supplies
Each Brocade ICX 6650 comes with two alternating-current (AC) power supplies. The Brocade ICX
6650 device also supports direct-current (DC) power supplies. The Brocade ICX 6650 is capable of
running on one power supply and one fan. The second set provide redundancy.
If the second power supply and fan slots are unused, you must cover them with filler panels.
NOTE
When running two power supplies, they must be of the same type: either two alternating-current (AC)
power supplies or two direct-current (DC) power supplies. AC and DC units cannot be mixed in a
device.
Installing and replacing a power supply unit
When installing or replacing a power supply unit, keep in mind the following:
Powering on the system
Brocade ICX 6650 Hardware Installation Guide 33