Installation guide

Brocade ICX 6430-C Compact Switch Hardware Installation Guide 41
53-1002817-02
Chapter
6
Troubleshooting
Diagnosing switch indicators
Table 14 describes the status of the LEDs and the how to troubleshoot.
Power and cooling problems
If the power indicator does not turn on when the power cord is plugged in, you may have a problem
with the power outlet, power cord, or internal power supply. However, if the unit powers off after
running for a while, check for loose power connections, power losses or surges at the power outlet,
and use the show chassis command to verify that the temperature is below the shutdown
threshold. If you still cannot isolate the problem, then the internal power supply may be defective.
In this case, contact Technical Support for assistance.
Installation
Verify that all system components have been properly installed. If one or more components appear
to be malfunctioning (such as the power cord or network cabling), test them in an alternate
environment where you are sure that all the other components are functioning properly.
TABLE 14 Troubleshooting chart
Symptom Action
Power LED is Off Internal power supply is disconnected.
Check connections between the device, the power cord, and the wall outlet.
Contact Technical Support.
Power LED is Amber Internal power supply has failed. Contact Technical Support.
Diag LED is Amber
The device self test has detected a fault.
Power cycle the device to try and clear the condition. If the condition persists,
contact Technical Support.
Link LED is Off
Verify that the device and attached device are powered on.
Be sure the cable is plugged into both the device and corresponding device.
Verify that the proper cable type is used and its length does not exceed specified
limits.
Check the adapter on the attached device and cable connections for possible
defects. Replace the defective adapter or cable if necessary.