34 Brocade ICX 6430-C Compact Switch Hardware Installation Guide
53-1002817-02
Temperature settings
4
Displaying the temperature
To display the temperature of a device, enter the show chassis command at any level of the CLI.
The show chassis command displays the power supply status, and temperature threshold levels for
fan speed.
NOTE
The displayed temperature reflects the temperature of the board inside the device.
Syntax: show chassis
Changing the temperature warning level
To change the temperature at which the device sends a warning message, enter a command
similar to the following at the Privileged EXEC level of the CLI.
Brocade# temperature warning 83
Syntax: temperature warning <decimal value>
The <value> variable is the temperature warning level, in Celsius. You cannot set this level higher
than
83°C . The temperature warning level must be at least 5 degrees Celsius less than the
temperature shut down level, which is automatically set by the device.
The following console and syslog message is displayed when the temperature reaches the warning
level:
!!! Temperature is over warning level on stack unit 1!!!
Temperature shutdown levels
When the temperature crosses the critical (shutdown) threshold levels, the device will reset after 5
minutes. The following console and syslog message is displayed:
!!! Temperature is over shutdown level, please shutdown your stack unit 1 to avoid
hw damage!!!
Brocade# show chassis
The stack unit 1 chassis info:
Power supply present, status ok
Fanless model
Sensor B Temperature Readings:
Current temperature : 55.0 deg-C
Sensor A Temperature Readings:
Current temperature : 50.0 deg-C
Warning level.......: 76.0 deg-C
Shutdown level......: 83.0 deg-C
Boot Prom MAC : 748e.f8ea.0360
Management MAC: 748e.f8ea.0360
=====