53-1002817-02 24 June 2013 Brocade ICX 6430-C Compact Switch Hardware Installation Guide Supporting software release 08.0.
Copyright © 2013 Brocade Communications Systems, Inc. All Rights Reserved. Brocade, Brocade Assurance, the B-wing symbol, BigIron, DCX, Fabric OS, FastIron, MLX, NetIron, SAN Health, ServerIron, TurboIron, VCS, and VDX are registered trademarks, and AnyIO, Brocade One, CloudPlex, Effortless Networking, ICX, NET Health, OpenScript, and The Effortless Network are trademarks of Brocade Communications Systems, Inc., in the United States and/or in other countries.
Contents About This Document How this document is organized . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii Supported hardware and software . . . . . . . . . . . . . . . . . . . . . . . . . . viii Document conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . viii Text formatting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . viii Command syntax conventions . . . . . . . . . . . . . . . . . . . . . . . . . . viii Command examples . .
Preparing the installation site . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Cabling infrastructure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Installation location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Rack-mount installation considerations. . . . . . . . . . . . . . . . . . . 14 Installing the device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Desktop installation. . . . . . . . . . . . . . .
BSMI statement (Taiwan) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 Regulatory compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 Appendix B Cautions and Danger Notices Cautions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 Danger notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Brocade ICX 6430-C Compact Switch Hardware Installation Guide 53-1002817-02
About This Guide This chapter contains the following sections: • Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 • Audience. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 • Document conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 • Document conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Document conventions This section describes text formatting conventions and important notice formats used in this document.
Getting technical help CAUTION A Caution statement alerts you to situations that can be potentially hazardous to you or cause damage to hardware, firmware, software, or data. DANGER A Danger statement indicates conditions or situations that can be potentially lethal or extremely hazardous to you. Safety labels are also attached directly to products to warn of these conditions or situations. Related publications The following Brocade Communications, Inc.
Getting technical help Document feedback Quality is our first concern at Brocade and we have made every effort to ensure the accuracy and completeness of this document. However, if you find an error or an omission, or you think that a topic needs further development, we want to hear from you. Forward your feedback to: documentation@brocade.
Chapter 1 Product Overview In this chapter • Hardware features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • Network and management interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • Port, system, and power status LEDs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • Power supplies. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1 Network and management interfaces FIGURE 2 ICX 6430-C12 rear panel Network and management interfaces The ICX 6430-C12 device includes the following management interfaces, and a reset button on the front panel of the device: • Console management interface (RJ45 serial port) • Out-of-band management interface (RJ45 port) • Reset button These RJ45 management ports are located together on the left side of the front panel. Refer to Figure 3.
Network and management interfaces 1 Reset button The reset button allows you to restart the system without switching the power supplies off and on or using the CLI or Web Management Interface. When reset button is pressed, the system resets and the software is reloaded. The button is directly below the power LED on the very left of the device’s front panel.
1 Port, system, and power status LEDs 1GbE RJ45 ports An ICX t6430-C device provides 12 RJ45 ports that reside on Slot 1 of the device. The 12 RJ45 ports operate at 10 Mbps or 100 Mbps half or full duplex, or at 1000 Mbps full duplex. Because all ports support automatic MDI or MDI-X operation, you can use straight-through cables for all network connections to PCs or servers, or to other devices or hubs.
Port, system, and power status LEDs FIGURE 4 1 Port status LEDs an ICX 6430-C12 device 1 Port status LEDs 2 PoE/PoE+ LEDs Table 2 lists the port status LEDs on an ICX 6430-C device and their corresponding conditions and status. TABLE 2 Port status LEDs LED Condition Status Out-of-band management port (2 LEDs) Off (right side) Offline On/Flashing (left side) Link-up. Flashing indicates the port is transmitting and receiving user packets.
1 Port, system, and power status LEDs FIGURE 5 1 System status LEDs on an ICX 6430-C12 device System status LEDs Table 3 lists the system status LEDs on an ICX 6430-C device and their corresponding conditions and status. TABLE 3 System status LEDs LED Condition Status PWR (Power) Green Power supply is operating normally. Amber Power supply fault. Off Power supply off. Flashing Green System self-diagnostic test in progress. System reloads automatically.
Port, system, and power status LEDs TABLE 4 1 Network connection-related LED states LED Desired state Meaning Abnormal state Meaning or action Ethernet (1-12, Slot 1) Link/Act On or flashing (Green) The port has established a valid link at 10, 100 or 1000 Mbps. Flashing indicates the port is transmitting and receiving user packets. Off A link is not established with the remote port. You can do the following: • Verify that the connection to the other network device has been properly made.
1 Port, system, and power status LEDs TABLE 4 Network connection-related LED states (Continued) LED Desired state Meaning Abnormal state Meaning or action SFP (F1 - F2, Slot 3) On or flashing (Green) The SFP port is operating. Flashing green indicates the port is transmitting and receiving user packets. Off A link is not established with the remote port. You can do the following: • Verify that the connection to the other network device has been properly made.
Power supplies 1 Power supplies An ICX 6430-C device has one standard power supply receptacle on the rear panel of the device for the AC power cord (Figure 6). FIGURE 6 ICX 6430-C AC power connection 1 Kensington lock hole 2 AC power supply socket Power supply usage The maximum power capacity of the ICX 6430-C12 device is 100W. 23W drawn from the AC line power supply input (of the total 100W capacity of the device) are necessary to power the ICX 6430-C12 device.
1 10 Power supplies Brocade ICX 6430-C Compact Switch Hardware Installation Guide 53-1002817-02
Chapter 2 ICX 6430-C Installation In this chapter • Items included with an ICX 6430-C device . . . . . . . . . . . . . . . . . . . . . . . . . . • Summary of installation tasks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • Installation precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • Preparing the installation site. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • Installing the device . . . . . . . . . .
2 Summary of installation tasks • A magnet mount option is available to order to mount the device securely on a metal surface. Summary of installation tasks Follow the steps listed in Table 5 to install your device. Details for each of these steps are provided on the pages indicated. TABLE 5 Installation tasks Task number Task Where to find more information 1 Ensure that the physical environment that will host the device has the proper cabling, ventilation, and clearance.
Installation precautions 2 CAUTION Never leave tools inside the device. Lifting precautions DANGER Make sure the rack or cabinet housing the device is adequately secured to prevent it from becoming unstable or falling over. DANGER Mount the devices you install in a rack or cabinet as low as possible. Place the heaviest device at the bottom and progressively place lighter devices above.
2 Preparing the installation site Preparing the installation site Before installing the device, plan its location and orientation relative to other devices and equipment. Cabling infrastructure Ensure that the proper cabling is installed at the site. For information about supported SFP and SFP+ transceivers and cable lengths and types, refer to the following Brocade website: http://www.brocade.com/downloads/documents/data_sheets/product_data_sheets/Optics_ DS.
Installing the device 2 • Mechanical loading: Do not place any equipment on top of a rack-mounted unit. • Circuit overloading: Be sure that the supply circuit to the rack assembly is not overloaded. • Grounding: Rack-mounted equipment should be properly grounded.
2 Installing the device 1. Attach the four adhesive feet to the bottom of the device. Refer to Figure 7. 2. Set the device on a flat desktop, table, or shelf near an AC power source. Make sure that adequate ventilation is provided for the system. A 7.62 cm (3-inch) clearance is recommended on each side. 3. If installing a single device only, refer to “Powering on the system” on page 30. Place each device squarely on top of the one below. 4.
Installing the device FIGURE 8 2 Attaching the mounting brackets for an ICX 6430-C device 3. Remove the two-post rack kit from the shipping carton. The kit contains four rack-mounting screws and four cage nuts. 4. Insert the cage nuts in the two-post rack where you want to mount the device. See Figure 8. 5. Using a Phillips screwdriver, mount the device in a two-post rack using four rack-mounting screws, as illustrated in Figure 9.
2 Installing the device FIGURE 9 Installing the device in a two-post rack 1 Rack-mounting screws 2 Cage nuts 6. If installing a single device only, proceed to “Powering on the system” on page 30. If installing multiple devices, mount them in the rack, one below the other.
Installing the device 2 Complete the following steps to mount the device directly to a wall. 1. Use tape to place the Wall Mount Holes Location template against the wall, in the same position that you plan to place the device against the wall. The Wall Mount Holes Location template serves as a guide to drilling the screws and mount anchors into the correct location on the wall in order to place the device in the desired location. 2.
2 Installing the device FIGURE 10 20 Preparing to wall mount the device 1 Drilled holes in wall 3 Wall mount screws 2 Wall mount anchors 4 4.0- 4.
Installing the device 2 5. With the port side of the device facing down, aim the mounting holes on the bottom panel of the device towards the wall mounting screws on the wall and hang the device securely against the wall, so that the the wall mount screws are inserted into the mounting holes. See Figure 11 and Figure 12.
2 Installing the device FIGURE 11 Wall mounting the ICX 6430-C device - View of rear panel * FIGURE 12 22 Wall mounting the ICX 6430-C device - View of the top panel Brocade ICX 6430-C Compact Switch Hardware Installation Guide 53-1002817-02
Installing the device 2 Wall mount installation using wall mount brackets NOTE You need a #2 Phillips screwdriver, a hammer, and a drill for wall mount installation. NOTE When mounting the device on a wall, Brocade recommends that you mount the device with the port side down. To mount the ICX 6430-C device to a wall, use the rack-mount kit that can be ordered seperately from the device (Brocade Part Number: ICX6400-RMK). The rack-mount kit is not included with the device.
2 Installing the device FIGURE 14 Wall mounting the ICX 6430-C device * 1 Drilled holes 2 Wall mount anchors 3 Wall mount screws Mounting the device with a magnet CAUTION Ensure that adequate ventilation is provided for the system. A 3 cm clearance is recommended above the device and 8 cm clearance is recommended on each side. CAUTION Do not install the switch in a position where it can easily become unstable and fall, causing injury or damage to the switch.
Installing the device 2 Use the magnet mount kit to mount the device on a metal wall or a metal surface, including underneath a metal desk. The magnet mount kit is available for order seperately from the device and consists of a single magnet sheet. Before mounting the device to a metal surface using the magnet sheet, ensure that the following requirements are met: • Adequate ventilation is provided for the system. Allow 3 cm. of clearance above the device and 8 cm. of clearance on each side.
2 Installing the device FIGURE 15 Attaching the logo side of the magnet sheet to the bottom panel of the ICX 6430-C device NOTE Do not install the rubber feet or remove the rubber feet if they are already installed.
Installing the device 2 Mounting the device on a metal surface or metal wall NOTE When mounting the device on a vertical metal surface, Brocade recommends that you mount the device with the port side down. Complete the following steps to securely mount an ICX 6430-C device on a metal surface or metal wall: 1. Ensure that the magnet sheet is attached to the bottom panel of the device. See “” and Figure 15. 2.
2 Installing the device FIGURE 17 An ICX 6430-C device securely mounted on a metal surface with ports facing down Mounting the device under a metal desk NOTE When mounting the device on a vertical metal surface, Brocade recommends that you mount the device with the port side down. CAUTION Do not mount the ICX 6430-C device directly underneath a desktop surface with the top panel facing downward.
Installing the device 2 CAUTION Ensure that adequate ventilation is provided for the system. A 7.62 cm (3-inch) clearance is recommended on each side.
2 Powering on the system FIGURE 19 The ICX 6430-C device securely mounted underneath a metal desk with the port side facing down Powering on the system After you complete the physical installation, you can power on the system. NOTE The socket should be installed near the equipment and should be easily accessible. 1. Remove the power cord from the shipping container. 2. Attach the AC power cord to the AC connector on the rear panel. 3. Insert the power cord plug into a 100V-240V outlet.
Chapter Configuring an ICX 6430-C device 3 In this chapter • IP address configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 IP address configuration You must configure at least one IP address using the serial connection to the CLI before you can manage the system using the other management interfaces.
3 32 IP address configuration Brocade ICX 6430-C Compact Switch Hardware Installation Guide 53-1002817-02
Chapter 4 Managing an ICX 6430-C device In this chapter • Temperature settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Temperature settings The device contains temperature sensors that the software reads based on a configurable device poll time. The device has two automatic speed fan control settings based on the temperature.
4 Temperature settings Displaying the temperature To display the temperature of a device, enter the show chassis command at any level of the CLI. The show chassis command displays the power supply status, and temperature threshold levels for fan speed. NOTE The displayed temperature reflects the temperature of the board inside the device. Brocade# show chassis The stack unit 1 chassis info: Power supply present, status ok Fanless model Sensor B Temperature Readings: Current temperature : 55.
Temperature settings 4 NOTE Brocade recommends that you shut down your stack unit to avoid any hardware damage.
4 36 Temperature settings Brocade ICX 6430-C Compact Switch Hardware Installation Guide 53-1002817-02
Chapter 5 Hardware Specifications In this chapter This section provides the hardware specifications for a ICX 6430-C device. • AC power supply specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • Physical dimensions and weight. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • Environmental considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • Pinouts and signalling . . . . . . . . . . . . . . . . . . . . . . . . .
5 Physical dimensions and weight Physical dimensions and weight Table 9 lists the physical dimensions and weight for the ICX 6430-C12 model. TABLE 9 ICX 6430-C12 Physical dimensions and weight Model Height Width Depth Weight ICX 6430-C12 43.94 mm (1.73 in.) 269.24 mm (10.6 in.) 213.36 mm (8.4 in.) 1.9 kg (4.19 lbs) Environmental considerations For optimal performance, operate or store your device in compliance with the following environmental conditions.
Pinouts and signalling TABLE 13 5 Console serial RJ45 management port pinouts (Continued) Pin number Definition Notes 3 UART0_TX Console Port 4 GND 5 GND 6 UART0_RX 7 NC 8 NC Console Port Cable specifications For information about supported transceivers and cable lengths and types, refer to the following Brocade website at: http://www.brocade.com/downloads/documents/data_sheets/product_data_sheets/Optics_ DS.
5 40 Pinouts and signalling Brocade ICX 6430-C Compact Switch Hardware Installation Guide 53-1002817-02
Chapter 6 Troubleshooting Diagnosing switch indicators Table 14 describes the status of the LEDs and the how to troubleshoot. TABLE 14 Troubleshooting chart Symptom Action Power LED is Off • • • Power LED is Amber Internal power supply has failed. Contact Technical Support. Diag LED is Amber • • The device self test has detected a fault. Power cycle the device to try and clear the condition. If the condition persists, contact Technical Support.
6 42 Diagnosing switch indicators Brocade ICX 6430-C Compact Switch Hardware Installation Guide 53-1002817-02
Appendix Regulatory Statements A USA (FCC CFR 47 Part 15 Warning) This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
A Japan (VCCI) Japan (VCCI) English translation of above statement This is Class A product based on the standard of the Voluntary Control Council For Interference by Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may arise. When such trouble occurs, the user may be required to take corrective actions. Japan power cord English translation of above statement ATTENTION: Never use the power cord packed with your equipment for other products.
A China China China-CCC Warning statements 在维修的时候一定要断开所有电源 (English translation“disconnect all power sources before service”) For non tropical use: 汉文 “仅适用于非热带气候条件下安全使用。” 藏文 安全 说明 和标 记 蒙古 文 壮文 Dan hab yungh youq gij dienheiq diuzgen mbouj dwg diegndat haenx ancienz sawjyungh. 维文 For altitude 2000 meter and below: 汉文 仅适用于海拔2000m以下地区安全使用。 藏文 安全 说明 和标 记 蒙古 文 壮文 Dan hab yungh youq gij digih haijbaz 2000m doxroengz haenx ancienz sawjyungh.
A BSMI statement (Taiwan) BSMI statement (Taiwan) English translation of above statement Warning: This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Regulatory compliance A Regulatory compliance Table 15 lists the Electromagnetic Compatibility (EMC), Immunity standards, and safety agency approval for the an ICX 6430-C device. TABLE 15 .
A 48 Regulatory compliance Brocade ICX 6430-C Compact Switch Hardware Installation Guide 53-1002817-02
Appendix Cautions and Danger Notices B Cautions A caution calls your attention to a possible hazard that can damage equipment. “Vorsicht” weist auf die Gefahr einer möglichen Beschädigung des Gerätes in. Une mise en garde attire votre attention sur un risque possible d'endommagement de l'équipement. Ci-dessous, vous trouverez les mises en garde utilisées dans ce manuel. Un mensaje de precaución le advierte sobre un posible peligro que pueda dañar el equipo.
B 50 Cautions CAUTION Ensure that the device does not overload the power circuits, wiring, and over-current protection. To determine the possibility of overloading the supply circuits, add the ampere (amp) ratings of all devices installed on the same circuit as the device. Compare this total with the rating limit for the circuit. The maximum ampere ratings are usually printed on the devices near the input power connectors.
B Cautions CAUTION Never leave tools inside the chassis. VORSICHT Lassen Sie keine Werkzeuge im Chassis zurück. MISE EN GARDE Ne laissez jamais d'outils à l'intérieur du châssis. PRECAUCIÓN No deje nunca herramientas en el interior del chasis. CAUTION Changes or modifications made to this device that are not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
B Danger notices CAUTION Do not mount the ICX 6430-C device directly underneath a desktop surface with the top panel facing downward. Only mount the ICX 6430-C device underneath a desktop by attaching it to the metal side surface of the desk, with the front panel and ports facing downward. VORSICHT N'installez pas le dispositif ICX 6430-C directement sous une surface de bureau, en orientant la face supérieure vers le bas.
B Danger notices Una señal de peligro le llama la atención sobre cualquier posible peligro que pueda ocasionar daños personales o la muerte. A continuación se dan las advertencias utilizadas en este manual. DANGER The procedures in this manual are for qualified service personnel. GEFAHR Die Verfahren in diesem Handbuch sind nur für qualifiziertes Wartungspersonal gedacht. DANGER Les procédures décrites dans ce manuel doivent être effectuées par le personnel de service qualifié uniquement.
B 54 Danger notices DANGER Disconnect the power cord from all power sources to completely remove power from the device. GEFAHR Ziehen Sie das Stromkabel aus allen Stromquellen, um sicherzustellen, dass dem Gerät kein Strom zugeführt wird. DANGER Débranchez le cordon d'alimentation de toutes les sources d'alimentation pour couper complètement l'alimentation du dispositif.