User guide
712 Brocade 6910 Ethernet Access Switch Configuration Guide
53-1002581-01
Sampling Traffic Flows
33
• Timeout – The time that the sFlow process will continuously send samples to the Collector
before resetting all sFlow port parameters. (Range: 0-10000000 seconds, where 0 indicates
no time out)
• The sFlow parameters affected by this command include the sampling interval, the receiver’s
name, address and UDP port, the time out, maximum header size, and maximum datagram
size.
• Max Header Size – Maximum size of the sFlow datagram header.
(Range: 64-256 bytes; Default: 128 bytes)
• Max Datagram Size – Maximum size of the sFlow datagram payload.
(Range: 200-1500 bytes; Default: 1400 bytes)
• Sample Rate – The number of packets out of which one sample will be taken.
(Range: 256-16777215 packets; Default: Disabled)
• Polling Interval – The interval at which counters are added to the sample datagram.
(Range: 0-10000000 seconds, where 0 disables this feature; Default: Disabled)
Interface
To configure flow sampling:
1. Click Interface, sFlow.
2. Select Configure Interface from the Step list.
3. Set the parameters for flow collector, the reset timeout, the payload, the sampling rate and the
polling interval.
4. Click Apply.
FIGURE 67 Configuring Interface Settings for Traffic Flow Sampling