User guide

538 Brocade 6910 Ethernet Access Switch Configuration Guide
53-1002581-01
CFM Commands
25
Default Setting
None
Command Mode
Privileged Exec
Command Usage
Use the mep keyword with this command to display the MEPs configured on this device as
DSAPs through the ethernet cfm mep command.
Using the mip keyword with this command to display the MIPs generated on this device by the
CFM protocol when the mip-creation method is set to either “default” or “explicit” by the
ethernet cfm domain command or the ma index name command.
Example
This example shows all MEPs configured on this device for maintenance domain rd.
Console#show ethernet cfm maintenance-points local mep
MPID MD Name Level Direct VLAN Port CC Status MAC Address
---- ---------------- ----- ------ ---- -------- --------- -----------------
1 rd 0 UP 1 Eth 1/ 1 Enabled 00-12-CF-3A-A8-C0
Console#
show ethernet cfm maintenance-points local detail mep
This command displays detailed CFM information about a local MEP in the continuity check
database.
Syntax
show ethernet cfm maintenance-points local detail mep [domain domain-name |
interface interface | level level-id]
domain-name – Domain name. (Range: 1-43 alphanumeric characters)
interface – Displays CFM status for the specified interface.
ethernet unit/port
unit - Unit identifier. (Range: 1)
port - Port number. (Range: 1-12)
port-channel channel-id (Range: 1-12)
level-id – Maintenance level for this domain. (Range: 0-7)
Default Setting
None
Command Mode
Privileged Exec