User guide
524 Brocade 6910 Ethernet Access Switch Configuration Guide
53-1002581-01
CFM Commands
25
clear ethernet cfm ais mpid Clears AIS defect information for the specified MEP PE
show ethernet cfm
configuration
Displays CFM configuration settings, including global settings, SNMP
traps, and interface settings
PE
show ethernet cfm md Displays configured maintenance domains PE
show ethernet cfm ma Displays configured maintenance associations PE
show ethernet cfm
maintenance-points local
Displays maintenance points configured on this device PE
show ethernet cfm
maintenance-points local
detail mep
Displays detailed CFM information about a specified local MEP in the
continuity check database
PE
show ethernet cfm
maintenance-points remote
detail
Displays detailed CFM information about a specified remote MEP in
the continuity check database
PE
Continuity Check Operations
ethernet cfm cc ma interval Sets the transmission delay between continuity check messages GC
ethernet cfm cc enable Enables transmission of continuity check messages within a specified
maintenance association
GC
snmp-server enable traps
ethernet cfm cc
Enables SNMP traps for CFM continuity check events GC
mep archive-hold-time Sets the time that data from a missing MEP is kept in the continuity
check database before being purged
CFM
clear ethernet cfm
maintenance-points remote
Clears the contents of the continuity check database PE
clear ethernet cfm errors Clears continuity check errors logged for the specified maintenance
domain and maintenance level
PE
show ethernet cfm errors Displays CFM continuity check errors logged on this device PE
Cross Check Operations
ethernet cfm mep
crosscheck start-delay
Sets the maximum delay that a device waits for remote MEPs to come
up before starting the cross-check operation
GC
snmp-server enable traps
ethernet cfm crosscheck
Enables SNMP traps for CFM continuity check events, in relation to the
cross-check operations between statically configured MEPs and those
learned via continuity check messages
GC
mep crosscheck mpid Statically defines a remote MEP in a maintenance association CFM
ethernet cfm mep
crosscheck
Enables cross-checking between the list of configured remote MEPs
within a maintenance association and MEPs learned through
continuity check messages
PE
show ethernet cfm
maintenance-points remote
crosscheck
Displays information about remote maintenance points configured
statically in a cross-check list
PE
Link Trace Operations
ethernet cfm linktrace
cache
Enables caching of CFM data learned through link trace messages GC
TABLE 124 CFM Commands (Continued)
Command Function Mode