User guide
Brocade 6910 Ethernet Access Switch Configuration Guide 285
53-1002581-01
Interface Commands
12
Eth Compliance Codes : 1000BASE-SX
Baud Rate : 1200 MBd
Vendor OUI : 00-30-D3
Vendor Name : AGILENT
Vendor PN : HFBR-5710L
Vendor Rev :
Vendor SN : 0111010843570877
Date Code : 01-11-01
DDM Info
Temperature : 37.56 degree C
Vcc : 3.29 V
Bias Current : 24.15 mA
TX Power : -5.79 dBm
RX Power : -34.03 dBm
Console#
test cable-diagnostics
This command performs cable diagnostics on the specified port to diagnose any cable faults
(short, open, etc.) and report the cable length.
Syntax
test cable-diagnostics interface interface
interface
ethernet unit/port
unit - Unit identifier. (Range: 1)
port - Port number. (Range: 1-12)
Command Mode
Privileged Exec
Command Usage
• Cable diagnostics are performed using Digital Signal Processing (DSP) test methods. DSP
analyses the cable by sending a pulsed signal into the cable, and then examining the reflection
of that pulse.
• This cable test is only accurate for cables 7 - 140 meters long.
• The test takes approximately 5 seconds. The switch displays the results of the test immediately
upon completion, including common cable failures, as well as the status and approximate
length of each cable pair.
• Potential conditions which may be listed by the diagnostics include:
• OK: Correctly terminated pair
• Open: Open pair, no link partner
• Short: Shorted pair
• Not Supported: This message is displayed for any Fast Ethernet ports that are linked up, or
for any Gigabit Ethernet ports linked up at a speed lower than 1000 Mbps.
• Impedance mismatch: Terminating impedance is not in the reference range.
• Ports are linked down while running cable diagnostics.