User guide

Brocade 6910 Ethernet Access Switch Configuration Guide 285
53-1002581-01
Interface Commands
12
Eth Compliance Codes : 1000BASE-SX
Baud Rate : 1200 MBd
Vendor OUI : 00-30-D3
Vendor Name : AGILENT
Vendor PN : HFBR-5710L
Vendor Rev :
Vendor SN : 0111010843570877
Date Code : 01-11-01
DDM Info
Temperature : 37.56 degree C
Vcc : 3.29 V
Bias Current : 24.15 mA
TX Power : -5.79 dBm
RX Power : -34.03 dBm
Console#
test cable-diagnostics
This command performs cable diagnostics on the specified port to diagnose any cable faults
(short, open, etc.) and report the cable length.
Syntax
test cable-diagnostics interface interface
interface
ethernet unit/port
unit - Unit identifier. (Range: 1)
port - Port number. (Range: 1-12)
Command Mode
Privileged Exec
Command Usage
Cable diagnostics are performed using Digital Signal Processing (DSP) test methods. DSP
analyses the cable by sending a pulsed signal into the cable, and then examining the reflection
of that pulse.
This cable test is only accurate for cables 7 - 140 meters long.
The test takes approximately 5 seconds. The switch displays the results of the test immediately
upon completion, including common cable failures, as well as the status and approximate
length of each cable pair.
Potential conditions which may be listed by the diagnostics include:
OK: Correctly terminated pair
Open: Open pair, no link partner
Short: Shorted pair
Not Supported: This message is displayed for any Fast Ethernet ports that are linked up, or
for any Gigabit Ethernet ports linked up at a speed lower than 1000 Mbps.
Impedance mismatch: Terminating impedance is not in the reference range.
Ports are linked down while running cable diagnostics.