Brocade 6910 Ethernet Access Switch Configuration Guide 273
53-1002581-01
Interface Commands
12
transceiver-threshold temperature
This command sends a trap when the transceiver temperature falls outside of the specified
thresholds.
Syntax
transceiver-threshold temperature {high-alarm | high-warning | low-alarm | low-warning}
threshold-value
high-alarm – Sends an alarm message when the high temperature threshold is crossed.
high-warning – Sends a warning message when the high temperature threshold is
crossed.
low-alarm – Sends an alarm message when the low temperature threshold is crossed.
low-warning – Sends a warning message when the low temperature threshold is crossed.
threshold-value – The threshold of the transceiver temperature. (Range: -20000 - 20000
in units of 0.01 Celsius)
Default Setting
None
Command Mode
Interface Configuration (Ethernet)
Command Usage
• Refer to the Command Usage section under the transceiver-threshold current command for
more information on configuring transceiver thresholds.
• Trap messages configured by this command are sent to any management station configured by
the snmp-server host command.
Example
The following example sets alarm thresholds for the transceiver temperature at port 1.
Console(config)interface ethernet 1/1
Console(config-if)#transceiver-threshold temperature low-alarm 97
Console(config-if)#transceiver-threshold temperature high-alarm -83
Console#