User guide

Brocade 6910 Ethernet Access Switch Configuration Guide 211
53-1002581-01
Web Authentication
10
web-auth login-attempts
This command defines the limit for failed web authentication login attempts. After the limit is
reached, the switch refuses further login attempts until the quiet time expires. Use the no form to
restore the default.
Syntax
web-auth login-attempts count
no web-auth login-attempts
count - The limit of allowed failed login attempts. (Range: 1-3)
Default Setting
3 login attempts
Command Mode
Global Configuration
Example
Console(config)#web-auth login-attempts 2
Console(config)#
web-auth quiet-period
This command defines the amount of time a host must wait after exceeding the limit for failed login
attempts, before it may attempt web authentication again. Use the no form to restore the default.
Syntax
web-auth quiet-period time
no web-auth quiet period
time - The amount of time the host must wait before attempting authentication again.
(Range: 1-180 seconds)
Default Setting
60 seconds
web-auth re-authenticate (Port) Ends all web authentication sessions on the port and forces
the users to re-authenticate
PE
web-auth re-authenticate (IP) Ends the web authentication session associated with the
designated IP address and forces the user to re-authenticate
PE
show web-auth Displays global web authentication parameters PE
show web-auth interface Displays interface-specific web authentication parameters
and statistics
PE
show web-auth summary Displays a summary of web authentication port parameters
and statistics
PE
TABLE 52 Web Authentication (Continued)
Command Function Mode