User guide

Brocade 6910 Ethernet Access Switch Configuration Guide 85
53-1002581-01
Event Logging
5
Command Usage
The command specifies the facility type tag sent in syslog messages. (See RFC 3164.) This type
has no effect on the kind of messages reported by the switch. However, it may be used by the
syslog server to sort messages or to store messages in the corresponding database.
Example
Console(config)#logging facility 19
Console(config)#
logging history
This command limits syslog messages saved to switch memory based on severity. The no form
returns the logging of syslog messages to the default level.
Syntax
logging history {flash | ram} level
no logging history {flash | ram}
flash - Event history stored in flash memory (i.e., permanent memory).
ram - Event history stored in temporary RAM (i.e., memory flushed on power reset).
level - One of the levels listed below. Messages sent include the selected level down to
level 0. (Range: 0-7)
Default Setting
Flash: errors (level 3 - 0)
RAM: debugging (level 7 - 0)
Command Mode
Global Configuration
Command Usage
The message level specified for flash memory must be a higher priority (i.e., numerically lower)
than that specified for RAM.
TABLE 19 Logging Levels
Level Severity Name Description
7 debugging Debugging messages
6 informational Informational messages only
5 notifications Normal but significant condition, such as cold start
4 warnings Warning conditions (e.g., return false, unexpected return)
3 errors Error conditions (e.g., invalid input, default used)
2 critical Critical conditions (e.g., memory allocation, or free memory error -
resource exhausted)
1 alerts Immediate action needed
0 emergencies System unusable