User guide

Brocade 6910 Ethernet Access Switch Configuration Guide 993
53-1002581-01
Connectivity Fault Management
42
FIGURE 301 Transmitting Delay-Measure Messages
Displaying Local MEPs
Use the Administration > CFM > Show Information (Show Local MEP) page to show information for
the MEPs configured on this device.
CLI References
“show ethernet cfm maintenance-points local” on page 537
“show ethernet cfm maintenance-points local detail mep” on page 538
Parameters
These parameters are displayed:
MEP ID – Maintenance end point identifier.
MD Name – Maintenance domain name.
Level – Authorized maintenance level for this domain.
Direction – Direction in which the MEP communicates CFM messages:
Down indicates that the MEP is facing away from the switch, and transmits CFM messages
towards, and receives them from, the direction of the physical medium.
Up indicates that the MEP faces inward toward the switch cross-connect matrix, and
transmits CFM messages towards, and receives them from, the direction of the internal
bridge relay mechanism.
Primary VLAN – Service VLAN ID.
Interface – Physical interface of this entry (either a port or trunk).
CC Status – Shows administrative status of CCMs.