User guide
Brocade 6910 Ethernet Access Switch Configuration Guide 993
53-1002581-01
Connectivity Fault Management
42
FIGURE 301 Transmitting Delay-Measure Messages
Displaying Local MEPs
Use the Administration > CFM > Show Information (Show Local MEP) page to show information for
the MEPs configured on this device.
CLI References
• “show ethernet cfm maintenance-points local” on page 537
• “show ethernet cfm maintenance-points local detail mep” on page 538
Parameters
These parameters are displayed:
• MEP ID – Maintenance end point identifier.
• MD Name – Maintenance domain name.
• Level – Authorized maintenance level for this domain.
• Direction – Direction in which the MEP communicates CFM messages:
• Down indicates that the MEP is facing away from the switch, and transmits CFM messages
towards, and receives them from, the direction of the physical medium.
• Up indicates that the MEP faces inward toward the switch cross-connect matrix, and
transmits CFM messages towards, and receives them from, the direction of the internal
bridge relay mechanism.
• Primary VLAN – Service VLAN ID.
• Interface – Physical interface of this entry (either a port or trunk).
• CC Status – Shows administrative status of CCMs.