User guide
986 Brocade 6910 Ethernet Access Switch Configuration Guide
53-1002581-01
Connectivity Fault Management
42
FIGURE 295 Configuring Maintenance End Points
To show the configured maintenance end points:
1. Click Administration, CFM.
2. Select Configure MEP from the Step list.
3. Select Show from the Action list.
4. Select an entry from MD Index and MA Index.
FIGURE 296 Showing Maintenance End Points
Configuring Remote Maintenance End Points
Use the Administration > CFM (Configure Remote MEP – Add) page to specify remote maintenance
end points (MEPs) set on other CFM-enabled devices within a common MA. Remote MEPs can be
added to a static list in this manner to verify that each entry has been properly configured and is
operational. When cross-checking is enabled, the list of statically configured remote MEPs is
compared against the MEPs learned through continuity check messages (CCMs), and any
discrepancies reported via SNMP traps.
CLI References
• “CFM Commands” on page 523
Command Usage
• All MEPs that exist on other devices inside a maintenance association should be statically
configured to ensure full connectivity through the cross-check process.