Technical data
IronWare Software Release 07.2.02j for Brocade FastIron switches
Release Notes v 1.0 Page 78 of 79
Defect ID: DEFECT000328640 Technical Severity: Medium
Summary: The error "Internal error! var_tree_get_one_entry_prefer_end() no entry but avail=57" is
displayed when IP address is created or removed on a virtual interface.
Symptom: Error message "Internal error! var_tree_get_one_entry_prefer_end() no entry but
avail=57" is displayed when the IP address is created or removed on a virtual interface.
Probability: Low
Feature: FCX Layer 3 Forwarding - IPV4 and IPV6 Function: Virtual interface (ve) Manager
Reported In
Release:
FI 07.0.01 Service Request ID: 268797
Defect ID: DEFECT000331021 Technical Severity: Critical
Summary: High CPU condition may occur due to a Next Hop memory leak.
Symptom: After running out of next hop resource, CPU usage became high because the device failed
to allocate the nexthop for hardware routes entries. CPU usage still remained high ( 96%)
even when all interfaces are disabled.
Probability: Medium
Feature: SX Layer 3 Forwarding - IPV4 and IPV6 Function: Data Forwarding
Reported In
Release:
FI 07.2.00 Service Request ID: 270255
Defect ID: DEFECT000331527 Technical Severity: Medium
Summary: Default dead-interval should be 3500 msec and current dead-interval should be 3500 msec”
for default timer values.
Feature: SX Layer3 Control Protocols Function: VRRP/VRRP-E and slow-start timer-
VRRP-E timer scale
Reported In
Release:
FI 07.2.02
Defect ID: DEFECT000332671 Technical Severity: Medium
Summary: Stackable FCX routes packets with the source MAC address of a physical port rather than
those with a MAC address of the VE interface.
Symptom: FCX is not sending the source MAC of the VE Interface.
Probability: High
Feature: FCX Layer 3 Forwarding - IPV4 and IPV6 Function: Host Networking stack (IPV4 and IPV6)
Reported In
Release:
FI 07.0.00 Service Request ID: 270088F