Defect ID: DEFECT000301831 Technical Severity: High
Summary: When strict priority is configured on the FGS624P, QoS priority 7 traffic dropped in
preference to QoS priority 0 traffic.
Feature: FCX Quality Of Service Function: TOS/QOS
Reported In
Release:
FI 07.1.00
Defect ID: DEFECT000302513 Technical Severity: Medium
Summary: Following OSPF area configuration change, type4 LSA may be incorrectly advertized.
Feature: SX Layer3 Control Protocols Function: OSPFV2 - IPV4
Reported In
Release:
FI 07.1.00
Defect ID: DEFECT000309026 Technical Severity: Medium
Summary: CLI is not taking more than one monitor command on the link-aggregate interface
configuration.
Feature: SX Traffic conditioning and Monitoring Function: port mirroring/monitoring
Reported In
Release:
FI 07.1.00
Defect ID: DEFECT000309344 Technical Severity: Medium
Summary: A 10G port flapped (down/up) when another port in the same module was manually
disabled or re-enabled.
Feature: SX Layer1 features Function: Auto Negotiation
Reported In
Release:
FI 07.1.00
Defect ID: DEFECT000321502 Technical Severity: Medium
Summary: A prompt with the incorrect VIF appears when VRRP VRID is configured.
Workaround: This is a display issue. It can be ignored safely.
Probability: High
Feature: SX Layer3 Control Protocols Function: VRRP/VRRP-E and slow-start timer-
VRRP-E timer scale
Reported In
Release:
FI 07.2.00 Service Request ID: 00264000