Technical data

IronWare Software Release 07.2.02j for Brocade FastIron switches
Release Notes v 1.0 Page 73 of 79
Defect ID: DEFECT000366413 Technical Severity: Critical
Summary: Static default route does not get updated after the master unit of the stack goes down.
Symptom: If there are multiple static default routes from both master and non-master units, the
default route from the master unit is correctly displayed in the routing table. But if the
master unit is powered down, this route will still be displayed instead of the route from the
non-master unit.
Probability: High
Feature: FCX Layer 3 Forwarding - IPV4 Function: STATIC ROUTES (IPV4)
Reported In
Release:
FI 07.2.02 Service Request ID: 665605
Defect ID: DEFECT000366766 Technical Severity: High
Summary: OSPFv2 Type4 ASBR Summary LSA is removed if the neighbor ASBR’s interface in the same
area is deleted.
Symptom: ASBR route is not advertised properly and subsequently, redistributed routes are not
installed in the routing table.
Probability: High
Feature: FI L3 Unicast Function: Control Plane - OSPF/OSPFv3
Reported In
Release:
FI 07.3.00 Service Request ID: 642515
Defect ID: DEFECT000368465 Technical Severity: High
Summary: When the sFlow collector is configured on a VE, FCX member units may reload
unexpectedly.
Symptom: When adding/removing RSTP config from the VLAN, member units may reload if sFlow is
configured on the VE for that VLAN.
Workaround: Disable sFlow or configure the collector on a physical interface instead of on the VE.
Probability: High
Feature: FCX Network Management Function: sFlow
Reported In
Release:
FI 07.2.02 Service Request ID: 669137
Defect ID: DEFECT000368913 Technical Severity: Medium
Summary: Memory tracking debug command may not work for all cases.
Symptom: Some memory leak conditions may not be detected using the “dm mem-leak” tool.
Probability: Low
Feature: SX_SYSTEM Function: UNDETERMINED
Reported In
Release:
FI 07.2.02