Defect ID: DEFECT000359744 Technical Severity: Medium
Summary: FESX code flash memory size is displayed incorrectly.
Symptom: FESX code flash memory is displayed as 16MB even if it is only 8MB in size.
Probability: High
Feature: SX Management Functionality Function: CLI and parser
Reported In
Release:
FI 07.2.02 Service Request ID: 640449
Defect ID: DEFECT000360173 Technical Severity: High
Summary: After enabling Single Spanning-Tree and reloading the device, the first port of the system
may be removed from VLAN 1.
Symptom: After 'spanning-tree single' is configured on the device and it is reloaded, Eth1 may be
removed from VLAN 1.
Probability: High
Feature: SX L2 Control Function: single spanning-tree
Reported In
Release:
FI 07.2.02 Service Request ID: 643797
Defect ID: DEFECT000361466 Technical Severity: Medium
Summary: Cannot communicate between Primary and Isolated Private VLANs.
Symptom: It is not possible to communicate between Primary and Isolated VLAN when Private VLANs
are configured.
Probability: High
Feature: SX L2 Forwarding Function: Private VLAN
Reported In
Release:
FI 07.2.02 Service Request ID: 636621, 650833
Defect ID: DEFECT000362478 Technical Severity: Medium
Summary: When CPU intensive tasks like repeated TFTP uploads are done, it may lead to loss of
heartbeat from Active to Standby Management modules, resulting in a switchover.
Symptom: When repeated TFTP uploads are done via INM, a switchover may be observed.
Probability: Low
Feature: SX Platform Specific features Function: Management module redundancy
Reported In
Release:
FI 07.2.02 Service Request ID: 592699