Defect ID: DEFECT000356415 Technical Severity: Critical
Summary: System unexpectedly resets after becoming unresponsive.
Symptom: Device displays LID message, then freezes and is unresponsive even from console.
Probability: Low
Feature: Sw licensing Function: Licensing All
Reported In
Release:
FI 07.3.00 Service Request ID: 642829
Defect ID: DEFECT000357491 Technical Severity: Medium
Summary: Rare error during baseline synchronization between Active and Standby Management
modules may lead to unexpected system reset.
Symptom: In very rare cases during baseline synchronization stage, an error may occur that can lead to
unexpected system reset.
Probability: Low
Feature: SX Platform Specific features Function: Management module redundancy
Reported In
Release:
FI 07.2.00 Service Request ID: 266664
Defect ID: DEFECT000357789 Technical Severity: Medium
Summary: After reload, CRC errors are seen on the link partner of member trunk ports.
Symptom: If a trunk is configured with member ports on two or more units and the ports used are
default stacking ports, on reload of the stack, the link partner of the trunk member ports
will observe CRC errors.
Workaround: Delete the trunk configuration, configure long-preamble on the trunk interfaces and then
re-deploy the trunk.
Probability: Medium
Feature: FCX Stacking Function: stack-ports
Reported In
Release:
FI 07.2.02 Service Request ID: 633009
Defect ID: DEFECT000358149 Technical Severity: High
Summary: Watchdog reset may occur during system bring-up.
Symptom: During reboot, system may become unresponsive and reload unexpectedly.
Probability: Low
Feature: FI Platform Specific features Function: system bringup
Reported In
Release:
FI 07.3.00 Service Request ID: 642829