Customer reported defects closed with code in Release R07.2.02e
Defect ID: DEFECT000330146 Technical Severity: High
Summary: Newly inserted Management Module may have invalid LID displayed, after which the
module cannot be upgraded via SW Licensing.
Symptom: On the Standby module, the LID value is displayed as ÿÿÿÿÿÿÿÿÿÿ. After a failover, the new
Active will have this same LID and thus cannot be upgraded.
Probability: High
Feature: SX Management Functionality Function: CLI and parser
Reported In
Release:
FI 07.2.02 Service Request ID: 595349
Defect ID: DEFECT000338861 Technical Severity: High
Summary: Device unexpectedly reloads when using SHA to verify sanctity of flash images.
Symptom: Device unexpectedly reloads when "verify sha <primary/secondary>" command is executed.
Probability: High
Feature: FI Embedded Management Function: CLI and parser
Reported In
Release:
FI 07.3.00 Service Request ID: 642003
Defect ID: DEFECT000338864 Technical Severity: Medium
Summary: Verification of flash images using MD5 gives incorrect and unpredictable results.
Symptom: When “verify md5 <primary/secondary>” is issued, the first run after a reboot returns all
zeros. Subsequent runs will show incorrect file size and MD5 hash.
Probability: High
Feature: FI Embedded Management Function: CLI and parser
Reported In
Release:
FI 07.3.00 Service Request ID: 642003, 645141
Defect ID: DEFECT000343157 Technical Severity: Medium
Summary: 2500W PoE power supply is misidentified as a 1250W power supply.
Symptom: 2500W power supply can allocate only half its capacity and is displayed incorrectly as
1350W or 1250W in the output of "show inline power detail" and "show power"
commands.
Probability: High
Feature: FI Platform Specific features Function: Chassis/fan/power
supplies/temperature sensors