Defect ID:
DEFECT000375567
Technical Severity:
Medium
Summary:
If hitless OS upgrade between incompatible SW code versions is attempted, a system reset may be
experienced.
Symptom:
If hitless OS upgrade between incompatible software code versions is attempted, a system reset may
be experienced.
Workaround:
Issue a regular 'reload' or 'boot system flash primary/secondary' instead of hitless-reload to
upgrade.
Probability:
High
Risk of Fix:
Low
Feature:
FI Infrastructure
Function:
SX Hitless OS upgrade
Reported In Release:
FI 07.3.00
Service Request ID:
680843
Defect ID:
DEFECT000376558
Technical Severity:
Medium
Summary:
Standby unit may reset if the Active stack unit is unplugged from power during hitless failover.
Symptom:
When hitless failover is configured and power is disconnected from the Active FCX of a stacked pair
running OSPFv2, the other FCX may reset soon afterwards. When it later recovers, all its interfaces
will remain down.
Probability:
Low
Feature:
FCX Layer3 Control Protocols
Function:
OSPFV2 - IPV4
Reported In Release:
FI 07.2.02
Service Request ID:
682809
Defect ID:
DEFECT000377048
Technical Severity:
Medium
Summary:
After stack failover causes preferred RIPv2 route to get deleted, backup Static route does not take
over.
Symptom:
If only the Active unit has RIP reachability and learns a better route than a configured Static route for
a given IP Next Hop, upon disabling power to the Active unit, the ensuing failover does not move up
the Static route as the best route on the new Active unit.
Probability:
Medium
Feature:
FCX Layer3 Control Protocols
Function:
RIP(v1-v2) - IPV4
Reported In Release:
FI 07.2.02
Service Request ID:
683931
Defect ID:
DEFECT000377054
Technical Severity:
Medium
Summary:
FCX "E" type FAN displays erroneous airflow direction in "show chassis" output.
Symptom:
The output of "show chassis" on FCX displays the airflow for "E" type fan as Back to Front even
though the fan actually provides airflow from the front to the back.
Probability:
Medium
Risk of Fix:
Low
Feature:
FI Platform
Function:
Power Supply/Temp Sensor/Fan Controller
Reported In Release:
FI 07.3.00
Service Request ID:
686691
Defect ID:
DEFECT000377090
Technical Severity:
Medium
Summary:
MAC table is not updated correctly when client is moved from PVLAN primary to PVLAN
community or from PVLAN community to PVLAN primary.
Symptom:
MAC table is not updated correctly when client is moved from PVLAN primary to PVLAN
community or from PVLAN community to PVLAN primary.
Probability:
High
Feature:
FCX L2 Forwarding
Function:
Private VLAN
Reported In Release:
FI 07.2.02
Service Request ID:
687429