Technical data
IronWare Software Release 07.2.02j for Brocade FastIron switches
Release Notes v 1.0 Page 52 of 79
Defect ID:
DEFECT000424399
Technical Severity:
Medium
Summary:
Software might not be able to read optical monitoring values in M-SX optics.
Symptom:
FLS Device may not be able to read Digital Optical Monitoring (DOM) information from Optical
Monitoring enabled optics.
Probability:
High
Feature:
DOM
Function:
DOM
Reported In Release:
FI 07.2.02
Service Request ID:
1094609
Customer reported defects closed with code in Release R07.2.02g
Defect ID:
DEFECT000341140
Technical Severity:
High
Summary:
PoE ports flap on modifying configuration through Web interface.
Symptom:
If a port name is configured via the Web interface, the link may flap.
Probability:
High
Feature:
FI Embedded Management
Function:
Web Management
Reported In Release:
FI 07.3.00
Service Request ID:
602297
Defect ID:
DEFECT000345889
Technical Severity:
High
Summary:
After disabling/re-enabling a module, SX chassis may stop accepting configuration commands.
Symptom:
After disabling/re-enabling a module, SX chassis does not accept any configuration commands and
instead prints "Error : HotSwap is in progress , please try again".
Probability:
Low
Feature:
FI Platform Specific features
Function:
HotSwap
Reported In Release:
FI 07.3.00
Service Request ID:
727841
Defect ID:
DEFECT000347007
Technical Severity:
Low
Summary:
Port may not be displayed in "show vlan" output if Single Spanning-Tree is configured.
Symptom:
With Single Spanning-Tree configured, a port that is displayed under the "show running-config"
output may not be displayed as a member of the VLAN when "show vlan" is entered.
Workaround:
Recover temporarily by removing and re-adding the port to the VLAN. However, this workaround
will not work across system resets.
Probability:
Medium
Feature:
SX L2 Control
Function:
single spanning-tree
Reported In Release:
FI 07.2.00
Service Request ID:
588187
Defect ID:
DEFECT000347486
Technical Severity:
Medium
Summary:
After Switchover, SX constantly displays code flash error messages on the console.
Symptom:
After Switchover, SX keeps displaying error messages such as "code_flash_block_write3: timeout,
f4413620:300010" on the console.
Probability:
Low
Feature:
FI Platform
Function:
Boot code/Flash/Kernel
Reported In Release:
FI 07.3.00
Service Request ID:
724459