Technical data

IronWare Software Release 07.2.02j for Brocade FastIron switches
Release Notes v 1.0 Page 51 of 79
Defect ID:
DEFECT000415275
Technical Severity:
Medium
Summary:
In some cases hardware route in FESX show as DROP and packets are not forwarded even if default
route is configured.
Symptom:
SX router may drop packets matching to the routes configured earlier to drop, but were deleted and
default route is configured.
Workaround:
This issue is not seen in 7.3c code and above.
Probability:
Low
Feature:
SX Layer 3 Forwarding - IPV4
Function:
Data Forwarding (IPV4)
Reported In Release:
FI 07.2.02
Service Request ID:
752703
Defect ID:
DEFECT000419065
Technical Severity:
Medium
Summary:
FastIron may have issues verifying the ssh signature with certain SSH clients.
Symptom:
FastIron devices may have issues in verifying the SSH signature with SSH-2.0-OpenSSH_4.3 version
of SSH clients causing SSH to stop working with the following error “key_verify failed for
server_host_key”.
Probability:
Medium
Feature:
FCX Management Functionality
Function:
IPv4/V6 SSH Service
Reported In Release:
FI 07.2.02
Service Request ID:
811769
Defect ID:
DEFECT000419248
Technical Severity:
Medium
Summary:
Spanning tree blocked the port that is forwarding ARP broadcasts.
Symptom:
In SX device, enabling a redundant link in a VLAN may occasionally cause loop in the network.
Workaround:
Disable and enable the port that is newly added to the VLAN.
Feature:
SX L2 Control
Function:
SpanningTree Protocols
Reported In Release:
FI 07.2.02
Service Request ID:
841043
Defect ID:
DEFECT000419899
Technical Severity:
Medium
Summary:
Erroneous Syslog messages reporting functioning FCX power supply units going down and coming up
immediately are generated due to signal noise level.
Symptom:
Erroneous and cosmetic Syslog messages about a Power Supply Unit being powered down and up are
displayed continuously even though the PSU functions correctly and provides uninterrupted AC power
to the switch/router.
Probability:
Medium
Feature:
FI Platform Specific features
Function:
Chassis/fan/powersupplies/temperature
sensors
Reported In Release:
FI 07.2.02
Service Request ID:
1080157
Defect ID:
DEFECT000423085
Technical Severity:
Medium
Summary:
PoE on SX can get stuck due to power glitch, no providing inline power or show correct info.
Symptom:
SX device may stop providing power to PDs such as access points and phones and PoE Modules
showing incorrect inline power allocation, even when no PD is attached.
Workaround:
Re-install the PoE firmware on the PoE controller, or RMA the affected unit if firmware
installation is not successful.
Probability:
Medium
Feature:
POE FW upgrade
Function:
POE FW upgrade
Reported In Release:
FI 07.2.02
Service Request ID:
760185