Technical data
IronWare Software Release 07.2.02j for Brocade FastIron switches
Release Notes v 1.0 Page 50 of 79
Defect ID:
DEFECT000406631
Technical Severity:
Medium
Summary:
Bridge TC Event log is missing on FastIron SX switches from code 07.2.00 and later.
Symptom:
SX device running Multiple Spanning Tree(MSTP) may not log the reception of Bridge TC Event.
Workaround:
Configure edge port on all switch ports where servers and laptops are to be connected.
Probability:
Medium
Feature:
SX L2 Control
Function:
SpanningTree Protocols
Reported In Release:
FI 07.2.02
Service Request ID:
733719
Defect ID:
DEFECT000408284
Technical Severity:
Medium
Summary:
Some OpenSSH versions are incompatible with the Fastiron devices when using scp.
Symptom:
FCX Devices may not be able to perform secure shell (SSH) login or secure copy (SCP) from client
running OpenSSH v5.5.p1 version. Previous versions work properly.
Workaround:
Use an earlier version of OpenSSH.
Probability:
High
Feature:
FCX Network Management
Function:
SSHv2/SCP V4/V6
Reported In Release:
FI 07.2.02
Service Request ID:
604551
Defect ID:
DEFECT000408747
Technical Severity:
Medium
Summary:
DHCP server not giving IP addresses to some hosts.
Symptom:
SX device running DHCP server may not offer IP addresses to hosts when moved from one subnet to
other.
Probability:
Medium
Risk of Fix:
Medium
Feature:
SX DHCP SERVER
Function:
DHCP
Reported In Release:
FI 07.3.00
Service Request ID:
1084792, 1085652
Defect ID:
DEFECT000408842
Technical Severity:
Medium
Summary:
Single SPAN STP loop may occur if a port is added to VLAN.
Symptom:
A loop may occur when a port is added to a VLAN that has dual mode port members with the same
VLAN and default VLAN, even when Single Spanning Tree is enabled.
Probability:
High
Risk of Fix:
Medium
Feature:
FCX L2 Control
Function:
single spanning-tree
Reported In Release:
FI 07.3.00
Service Request ID:
737569
Defect ID:
DEFECT000410873
Technical Severity:
Medium
Summary:
Flash can get into locked state after performing a "copy flash to flash" operation.
Symptom:
Execution of the “copy flash to flash” command in an SX device may lock the flash resulting in the
following error message “Flash access in progress. Please try later” when a write memory operation is
initiated.
Feature:
FCX Management Functionality
Function:
CLI and parser
Reported In Release:
FI 07.2.02
Service Request ID:
749897
Defect ID:
DEFECT000412141
Technical Severity:
Medium
Summary:
sflow does not work for member units of the FGS stack if the uplink is 10G.
Symptom:
sflow does not work for member units of the FGS stack if the uplink is 10G and configured with IPv6
collector.
Feature:
FCX Network Management
Function:
sFlow
Reported In Release:
FI 07.2.02
Service Request ID:
716053