Installation guide

Brocade FastIron SX Series Chassis Hardware Installation Guide 81
53-1002500-01
Displaying chassis status and temperature readings
4
Fans
Fan <number> For FSX 800, this field displays information about fans 1 through 6. Fan locations
are:
Fan 1 – Left-most fan in bottom row
Fan 2 – Middle fan in bottom row
Fan 3 – Right-most fan in bottom row
Fan 4 – Left-most fan in top row
Fan 5 – Middle fan in top row
Fan 6 – Right-most fan in top row
For the FSX 1600, this field displays information about fans 1 and 2. Fan locations
are:
Fan 1 – This is Fan A and is the right-most fan in the rear of the chassis.
Fan 2 – This is Fan B and is the right-most fan in the rear of the chassis.
<Fan status> The status of a fan can be one of the following:
OK – The fan is functioning properly and is keeping the temperature of each
module within an acceptable temperature range.
Failed – The fan is not functioning properly or the fan control module cannot
control the fan.
Speed <Operating mode> The operating mode of a fan can be one of the following:
Auto (automatic) – This is the default
Manual
<Current fan speed> The fan speed for the FSX 800 can be one of the following:
1 (low) – The fan is functioning at 25 percent of capacity.
2 (medium-low) – The fan is functioning at 37 percent of capacity.
3 (medium) – The fan is functioning at 50 percent of capacity.
4 (high) – The fan is functioning at 100 percent of capacity.
The current fan speed is shown in double brackets.
Temperature
Fan controlled temperature The FSX 800 and FSX 1600 display the temperature reading of the management,
interface, and switch fabric modules:
Rule 1/3 – The highest temperature reading of the management module or
modules.
Rule 2/3 – The highest temperature reading of all the interface modules.
Rule 3/3 – The highest temperature reading of the switch fabric modules.
Fan speed switching
temperature thresholds
The FSX 800 and FSX 1600 display the configured temperature thresholds for the
management, interface, and switch fabric modules.
Rule 1/3 (MGMT CARDS THERMAL PLANE) – The configured temperature
thresholds for the management module or modules.
Rule 2/3 – (LINE CARDS THERMAL PLANE) – The configured temperature
thresholds for all the interface modules.
Rule 3/3 – (SWITCH FABRIC CARDS THERMAL PLANE) – The configured
temperature thresholds for the switch fabric modules.
The output displays fan speed information for each of the above thermal planes.
The FSX 800 chassis devices has four fan speeds as illustrated in Figure 45 on
page 84.
Slot <number> Temperature The temperature of each module.
On the FSX 800 and FSX 1600, the management modules are in slots 9 and
10 and the switch fabric modules are SF 1 and SF 2.
TABLE 23 Chassis status and temperature information (Continued)
Field Definition