Installation guide
Brocade FastIron SX Series Chassis Hardware Installation Guide 73
53-1002500-01
Connecting network devices
3
3. Insert the cable connector (a tab on each connector should face up) into the port connector or
until the tab locks into place.
Cleaning fiber optic modules
To avoid problems with connections between fiber optic modules (SFP (mini-GBIC), SFP+, or XFP)
and the fiber cable connectors, it is strongly recommended that you clean both connectors each
time you disconnect and reconnect them. Refer to “Cleaning the fiber optic connectors” on
page 105.
Automatic MDI or MDIX detection
All 10/100 and Gigabit Ethernet copper ports on FastIron devices support automatic Media
Dependent Interface (MDI) and Media Dependent Interface Crossover (MDIX) detection. This
feature is enabled on all 10/100 and Gigabit copper ports by default. For each port, you can
disable auto MDI or MDIX, or designate the port as an MDI port, or an MDIX port.
For more information about this feature refer to the FastIron Configuration Guide.
Using a CX4 transceiver
A twin-axial 10G copper CX4 XFP transceiver can be installed in any 10G port. For a link to operate
properly, both sides must use identical CX4 transceivers. Refer to Figure 43.
The CX4 transceiver requires a 15 meter CX4-grade cable with 24 or 26 American Wire Gauge
(AWG). This cable can be purchased from Brocade. Refer to part number CAB-CX4-0050 when
ordering. Refer to Figure 44.
NOTE
The CX4 transceiver is not hot-swappable.
FIGURE 43 CX4 transceiver
1CX4 transceiver
1