Power supply requirements for 10Gx4 interface modules
Table 12 lists the power supply requirements for each type of router when installing
BR-MLX-10GX4-X interface modules.
TABLE 12 Power supply requirements for BR-MLX-10GX4-X and BR-MLX-10Gx4-X-ML interface modules
Router type Number of Gen-2
10GX4-X interface
modules installed
Power supply requirements
MLXe-4 three one 1200W PSU
for 1+1 redundancy, install two 1200W PSU
four two 1200W PSU
for 2+2 redundancy, install four 1200W PSU
MLX-4 and
Brocade NetIron
XMR 4000
four one 1200W PSU
for 1+1 redundancy, install two 1200W PSU
MLXe-8 seven two 1200W PSU
for 2+2 redundancy, install four 1200W PSU
eight three 1200W PSU
for 3+1 redundancy, install four 1200W PSU
Brocade NetIron
XMR 8000
eight two 1200W PSU
for 2+2 redundancy, install eight 1200W PSU
All 16-slot routers sixteen four 1200W PSU
for 4+4 redundancy, install eight 1200W PSU
All 32-slot routers thirty-two four 2400W PSU
for 4+4 redundancy, install eight 2400W PSU