Technical data

Page 20
Critical NOS services may terminate, resulting in a switch reboot if the switch is loaded with a
large number of VLANs configured for "no shutdown." Configuring the switch with all VLAN
interfaces set to “shutdown” will prevent this from occurring and will not affect any functionality.
The VCS replace command is not supported on VDX 2730.
Known Issues
Note: The following features are not supported for this release of VDX 2730:
Intel Niantic Mezz card and LOM
LACP default mode for PXE boot
Defect ID:
DEFECT000414898
Technical Severity:
Medium
Summary:
ISMIC support for stateless IPv6 addresses is not present.
Symptom:
ISMIC support for stateless IPv6 addresses is not present.
Feature:
Embedded Platform Services
Function:
Other
Reported In Release:
NOS 2.1.1_fuj
Defect ID:
DEFECT000389724
Technical Severity:
Medium
Summary:
One member within a vLAG may not not sync up although the port was online.
Symptom:
In rare cases, one member within a vLAG may not sync up although the port was online
Feature:
CEE-LAYER2
Function:
LAG/TRUNKING
Reported In Release:
NOS 2.1.1_fuj
Probability:
Low
Defect ID:
DEFECT000403990
Technical Severity:
Medium
Summary:
Configuration of User Assigned Name from MMB doesn't sustain across reboot
Symptom:
Configuration of User Assigned Name from MMB doesn't push down to the switch
Feature:
Embedded Platform Services
Function:
Other
Reported In Release:
NOS 2.1.1_fuj
Probability:
High
Defect ID:
DEFECT000405183
Technical Severity:
Medium
Summary:
'vcs replace' is not supported in NOS 2.1.1_fuj release but will display as an operand
Symptom:
User will see “Error: Command is not supported as the local node is not in cluster.” , on executing
command ‘vcs replace’.
Feature:
VCS-infra-dcm
Function:
DCM - Other
Reported In Release:
NOS 2.1.1_fuj
Probability:
High
Defect ID:
DEFECT000406824
Technical Severity:
Medium
Summary:
When an internal port is disabled by the e-keying function with port config "no shut", there is no
error message when user attempts to enable it
Symptom:
When a user attempts to enable an internal port, which has been disabled by e-keying using port
config "no shut:" no error message is displayed.
Feature:
CEE-Protocol
Function:
NSM
Service Request ID:
233447792
Reported In Release:
NOS 2.1.1_fuj
Probability:
High