Technical data
Page 20
• Critical NOS services may terminate, resulting in a switch reboot if the switch is loaded with a
large number of VLANs configured for "no shutdown." Configuring the switch with all VLAN
interfaces set to “shutdown” will prevent this from occurring and will not affect any functionality.
• The VCS replace command is not supported on VDX 2730.
Known Issues
Note: The following features are not supported for this release of VDX 2730:
• Intel Niantic Mezz card and LOM
• LACP default mode for PXE boot
Defect ID:
DEFECT000414898
Technical Severity:
Medium
Summary:
ISMIC support for stateless IPv6 addresses is not present.
Symptom:
ISMIC support for stateless IPv6 addresses is not present.
Feature:
Embedded Platform Services
Function:
Other
Reported In Release:
NOS 2.1.1_fuj
Defect ID:
DEFECT000389724
Technical Severity:
Medium
Summary:
One member within a vLAG may not not sync up although the port was online.
Symptom:
In rare cases, one member within a vLAG may not sync up although the port was online
Feature:
CEE-LAYER2
Function:
LAG/TRUNKING
Reported In Release:
NOS 2.1.1_fuj
Probability:
Low
Defect ID:
DEFECT000403990
Technical Severity:
Medium
Summary:
Configuration of User Assigned Name from MMB doesn't sustain across reboot
Symptom:
Configuration of User Assigned Name from MMB doesn't push down to the switch
Feature:
Embedded Platform Services
Function:
Other
Reported In Release:
NOS 2.1.1_fuj
Probability:
High
Defect ID:
DEFECT000405183
Technical Severity:
Medium
Summary:
'vcs replace' is not supported in NOS 2.1.1_fuj release but will display as an operand
Symptom:
User will see “Error: Command is not supported as the local node is not in cluster.” , on executing
command ‘vcs replace’.
Feature:
VCS-infra-dcm
Function:
DCM - Other
Reported In Release:
NOS 2.1.1_fuj
Probability:
High
Defect ID:
DEFECT000406824
Technical Severity:
Medium
Summary:
When an internal port is disabled by the e-keying function with port config "no shut", there is no
error message when user attempts to enable it
Symptom:
When a user attempts to enable an internal port, which has been disabled by e-keying using port
config "no shut:" no error message is displayed.
Feature:
CEE-Protocol
Function:
NSM
Service Request ID:
233447792
Reported In Release:
NOS 2.1.1_fuj
Probability:
High