QuickSpecs
P2000 G3 FC
P2000 G3 SAS
P2000 G3 10GbE
iSCSI
MSA2000i G2 1GbE
iSCSI
Capacity
Minimum / with
maximum additional
drive enclosures
LFF
: 7.2 TB SAS
or 24 TB SAS MDL or
SATA
w/ 7 LFF enclosures:
57.6 TB SAS
or 192 TB SAS MDL or
SATA
SFF
: 7.2 TB SAS
or 12 TB SATA
w/ 5 D2700 JBODs:
44.7 TB SAS
or 74.5 TB SATA
LFF:
7.2 TB SAS
or 24 TB SAS MDL or
SATA
w/ 7 LFF enclosures:
57.6 TB SAS
or 192 TB SAS MDL or
SATA
SFF:
7.2 TB SAS
or 12 TB SATA
w/ 5 D2700 JBODs:
44.7 TB SAS
or 74.5 TB SATA
LFF
: 7.2 TB SAS
or 24 TB SAS MDL or
SATA
w/ 7 LFF enclosures:
57.6 TB SAS
or 192 TB SAS MDL or
SATA
SFF
: 7.2 TB SAS
or 12 TB SATA
w/ 5 D2700 JBODs:
44.7 TB SAS
or 74.5 TB SATA
LFF
: 7.2 TB SAS
or 24 TB SAS MDL or
SATA
w/ 4 drive enclosures
36 TB SAS
or 120 TB SAS MDL or
SATA
SFF
: 7.2 TB SAS
or 6 TB SATA
w/ 3 MSA70 JBODs:
29.7 TB SAS
or 24.7 TB SATA
Controller Cache
2 GB per controller 2 GB per controller 2 GB per controller 1 GB per controller
Total LUNs
512 512 512 512
Host connect
P2000 & MSA2000 have
1 or 2 controllers, EVA
has 2 controllers
standard
Two 8 Gb
Fibre Channel ports or
Two 8Gb FC and two
1GbE iSCSI ports
per controller
Four 6 Gb (x4)
SAS ports
per controller
Two 10 GbE iSCSI
ports per controller
Four 3 Gb
SAS ports
per controller
Maximum Drives
w/ expansion
96 LFF/149 SFF 96 LFF/149 SFF 96 LFF/149 SFF
60 LFF/99 SFF
Maximum host
supported
(dual controller)
64
8 single path
4 dual path
64 16
Optional software:
Snapshot, clone,
Remote Snap
Snapshot, 64 standard
(max 512)
Clone (standard)
Remote Snap
Snapshot, 64 standard
(max 512)
Clone (standard)
Snapshot, 64 standard
(max 512)
Clone (standard)
Snapshot (max 255)
clone
Use for Storage
Primary Storage
with SAS drives.
Secondary with SATA
Primary Storage
with SAS drives.
Secondary with SATA
Primary Storage
with SAS drives.
Secondary with SATA
Primary Storage
with SAS drives.
Secondary with SATA
NOTE:
maximum available storage capacity depends on the RAID level being implemented
Product Technology
8Gb Fibre Channel
controller
Two host ports per FC controller shipped with SFPs. The P2000 G3 FC controller can run in either
point-to-point or FCAL (loop). The default is FCAL which is used in Direct Connect, particularly with
two controllers. The PtP (fabric) mode is used with almost all switches.
Combo controller with
FC and iSCSI ports
This ingenious dual-protocol "combo" controller supports a full FC SAN through the 8Gb FC ports,
while designating the two 1 GbE iSCSI ports to enable remote replication over iSCSI protocol and
perform as an iSCSI target. This allows economical sharing of the storage resource (the P2000 G3
array) with one department needing the performance afforded by the 8 Gb FC ports while
simultaneously supporting another department with lesser performance needs and a budget only
allowing a 1GbE iSCSI network.
6Gb SAS controller
Four host ports per 6Gb 4x SAS controller.
10GbE iSCSI
controller
Two 10GbE ports per G3 10GbE iSCSI controller. Ports are ready for the choice of SFP (none
included)
Supports the ProCurve and ISS versions of the following 10GbE parts for use in the controllers:
HP 10Gb Cables
QuickSpecs
HP StorageWorks P2000 G3 Modular Smart Array
Systems
Family Information
DA - 13551 Worldwide QuickSpecs — Version 7 — 9.27.2010
Page 8